OPERATING INSTRUCTIONS___________________________________________________________________________

6.Make sure that the hook-up leads offer sufficient current capability and low resistance between the power supply and the circuits being powered. The hook-up leads supplied with the power supply are rated for 4 amps.

7.If the red OVERLOAD indicator lights, too much load has been placed on the supply. This will cause voltage and current to drop and prevent proper operation of the FIXED 5 V supply. To correct this situation, the load on the supply much be decreased so that no more than 4 amps of current are required.

NOTE

If decreasing the load does not cause the overload indicator to turn off, the overvoltage protection circuitry has turned on. In order to return the supply to normal operation, the output voltage must be decreased (or the external voltage source must be removed) and the power must be momentarily shut off.

28

Image 32
Contents Instruction Manual Test Instrument Safety DC Power Supply Table of Contents Introduction Introduction Features Isolated Output Overload ProtectionReverse Polarity Protection HOOK-UP CablesSpecifications B SuppliesFixed 5V Supply GeneralControls and Indicators Supply Controls and IndicatorsControls and Indicators Constant Current Indicator Fixed 5V Supply Terminals and Indicator Rear Panel Controls Line Voltage Select Switches. CombinationRear panel controls Safety Precautions Equipment PrecautionsOperating Instructions Independent USE of a or B SupplyOperating Instructions Hook-up Operating Instructions Independent operation grounding possibilities sheet 2 Setting Current Limit Setting Current limit Constant voltage/constant current characteristic Series Tracking OperationOperating Instructions Operating Instructions Operating Instructions Parallel Tracking Operation Parallel tracking operation grounding possibilities sheet 1 Parallel tracking operation grounding possibilities sheet 2 Fixed 5 V Power Supply Operation Grounding possibilities for fixed 5 V power supply sheet 1 Grounding possibilities for fixed 5 V power supply sheet 2 Operating Instructions Electronics Manufacturing ApplicationsElectronics Servicing Battery Charging Electronics Design LABElectronics Education Split SupplyPage Page Page Page Page Page Maintenance Fuse ReplacementService Information Limited One-Year Warranty Test Instrument Safety Manual DE Instrucciónes Fuente DE Poder DE CD Triple Seguridad DEL Instrumento DE Prueba Advertencia Seguridad DEL Instrumento DE Prueba Instrucciones DE OperaciónIntroduccion Salida Triple Fuente Fija DEDOS Fuentes DE O a Característica DE Rastreo UnicaProtección DE Polaridad Inversa Cables Salida AisladaProtección Contra Sobreflujo Especificaciones Fuentes a Y BGeneral Controles E Indicadores Figura 1. Controles e indicadores del panel frontal Indicador Constant Current Controles E Indicadores DE LA Fuente BIndicadores Y Controles DE LA Fuente DE Controles DEL Panel TraseroFigura 2. Controles del panel trasero Precauciones Para Seguridad USO Independiente DE LA Fuente a O BInstrucciones DE Operación Page Page Figura 4. Operación de voltaje constante típica Operación de corriente constante típica Característica de voltaje constante/corriente constante Operación DE Rastreo EN SeriePage Page Instrucciones DE Operación Operación DE Rastreo EN Paralelo Page Page Operación DE LA Fuente Fija DE Page Page Instrucciones DE Operación Servicio Electrónico Manufactura ElectrónicaLaboratorio DE Diseño Electrónico Educación EN ElectrónicaCarga DE Baterias Fuente DivididaAplicaciones Aplicaciones Aplicaciones Aplicaciones Aplicaciones Aplicaciones Mantenimiento Información de Servicio Garantía Limitada de Un Ano Seguridad DE EL Equipo DE Prueba Declaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA 2005 B&K Precision Corp