American Power Conversion XS 450 -48 Battery Installation, DC Load Return cable connections

Page 28

Figure 3.7-7 Large Load and Small Load Return Module

DC Load Return cable connections

The battery return module has a shunt installed and the load return modules do not. The small return has 40 pairs of M5 threaded holes on 1.59 cm (5/8 in.) centers. One set of M8 threaded holes on 2.54 mm (1 in.) and 4.45 mm (1.75 in.) centers is also provided on the small return module. The large return has 6 pairs of M8 threaded holes on 2.54 mm (1 in.) and 4.45 mm (1.75 in.) centers

3.8 Battery Installation

WARNING: Make certain that the battery polarity is correct when making connections to the Magnum XS 450 Power System. Incorrect connection could cause severe equipment damage.

Battery Tray Installation

Install Battery Shelf 1 in bottom of power system. Use M6 hardware in the lowest 2 holes on each corner post to mount the battery shelf. Battery Shelf 2 is mounted 35.5 cm (14 in.) above Battery Shelf 1.

Battery Installation

Each Battery tray is designed to hold four 12-Volt Valve Regulated Lead Acid (VRLA) type Mono-block batteries. Always follow the battery vendor’s installation instructions for proper set-up of batteries. Installation of batteries should also be done with due consideration to all applicable local codes. The end user is responsible for meeting any and all local codes issues, including, but not limited to, Battery Spill Containment Systems.

Battery Disconnect Module Installation

The Battery Disconnect Module requires one open module position and is typically installed in the lowest position. Insert the module in the power system such that the holes in the module dc bus line up with the holes in the power system dc bus. Use M8 hardware to secure the buses together. Use M5 hardware to secure the front lip to the power system frame. Use M6 hardware to secure the rear of the module to the power system frame.

Magnum XS 450 Power System –48 VDC User’s Manual

Page 23

Image 28
Contents Magnum XS Vdc Power System User’s Manual Table of Contents Magnum XS 450 Power System -48 VDC User’s Manual Specifications Revision History Revision Date DescriptionSafety First General PrecautionsIntroduction General InformationMagnum XS 450 Power System -48 VDC User’s Manual How to Use This Manual Installation Mechanical InstallationUnpacking Equipment Room / Location1 Door Clearance Dimensions Mounting VentilationAC Power Connections AC Kit with Three Phase SpreaderAC Line AC Neutral Earth Ground AC Kit with Phoenix Terminals Only AWGRectifier Shelf and Module Installation Rectifier Shelf Mechanical Rectifier Shelf Serial CommunicationsRectifier AC Input Connections Rectifier Module Installation DC Distribution Module InstallationModule Selection Merlin Gerin 28 Circuit Breaker Module Installation 1 28 Circuit Breaker ModuleMerlin Gerin 12 Circuit Breaker Module Installation NH2 Fuse Module Installation Circuit Breaker Rating Ordering NumberDC Cabling General Instructions 3 NH2 Fuse ModuleDC Distribution Installation Circuit Breaker Installation2 Merlin Gerin 28 CB Module Installation Detail C60 C120 Total 4 CB Alarm Interface Board 28 circuit breaker module Installing a fuse in the NH2 Fuse Module DC Load Return Module InstallationBattery Installation Battery Tray InstallationBattery Installation Battery Disconnect Module InstallationNegative Battery Cable Connections 1 Battery Cable ConnectionsPositive Battery Cable Connections Battery Return Module InstallationBattery Temperature Probe Installation Monitoring and Relay Output Connections DC System GroundingNetwork Management Card RJ45 Ethernet Connector Smart Cable DB9 ConnectionRelay Output Connections N/C-CExternal Alarm Input Connections Open Closed NO-C NC-CElectrical Installation Battery Visual and Safety InspectionCommissioning Pre-Commissioning InspectionCommissioning Battery Temperature Compensation LVD TestCircuit Breaker/ Fuse Test User InputsFinal Inspection LVDTechnical Description OperationRectifier Management Battery Management DC DistributionExternal Alarm Inputs Input Relays Alarm Outputs Output RelaysCustomer Interface Board Preventive Maintenance System Visual and Safety InspectionEquipment InspectionTest Battery Current Test System Temperature TestBattery Temperature Test Battery Preventive Maintenance Procedure Specifications AC Input DCPM28HN54SH0 RectifierMechanical EnvironmentalCompliance EMCAPC Worldwide Customer Support Limited Product Warranty

XS 450 -48 specifications

The American Power Conversion (APC) XS 450 -48 is a reliable and efficient power supply solution designed for critical applications requiring a consistent and stable power source. This solution is particularly beneficial for telecommunications, data centers, and industrial settings where power reliability is paramount.

One of the key features of the XS 450 -48 is its ability to deliver 450 watts of continuous power, ensuring that connected devices receive uninterrupted power supply. Its 48-volt output makes it ideal for telecom requirements, where 48V systems are standard. The unit provides a compact and space-saving design, making it suitable for installation in rack-mounted configurations, optimizing the utilization of valuable real estate in server rooms or equipment racks.

The XS 450 -48 utilizes advanced technologies that enhance its performance and reliability. It is equipped with an active power factor correction (PFC) system that significantly reduces harmonic distortion. This feature not only improves system efficiency but also complies with various regulations concerning power quality. Additionally, the power supply includes built-in over-voltage protection, over-current protection, and short-circuit protection, ensuring that both the power supply and the connected devices are safeguarded against electrical faults.

The unit is designed for high efficiency, often exceeding 90% under full load conditions. This not only reduces energy costs but also minimizes heat generation, contributing to a quieter operation environment. The XS 450 -48's intelligent thermal management system allows it to operate in a range of temperatures, making it highly versatile and adaptable to varying environmental conditions.

Furthermore, monitoring and management capabilities are integrated into the XS 450 -48 with optional external monitoring systems. These systems provide critical insights, allowing technicians to track real-time performance metrics, detect potential issues early on, and perform preventive maintenance.

In conclusion, the American Power Conversion XS 450 -48 stands out as a robust power supply solution that combines reliable performance, advanced protection features, and high efficiency. Its design caters to the specific needs of telecommunications and data centers, making it an indispensable asset for maintaining the uptime and integrity of critical systems. With its range of features and reliability, the XS 450 -48 continues to be a preferred choice among professionals in the field.