American Power Conversion XS 450 -48 user manual Battery Return Module Installation

Page 30

Battery Return Module Installation

The battery return module is typically installed in the top return module position. To install the battery return module, loosen the 4 M5 X 8 Phillips head screws on the back of the unit. The slots will allow the module to be aligned precisely. Position the module in an open return position in the unit. Align the holes in the return module with the holes in the return bus and insert 2 M8 X 20 cap screws with lock washers and flat washers. Align the holes in the return module with the holes in the front of the cabinet and insert 2 M5 Phillips screws. Tighten the M8 cap screws, then the M5 screws and finally the M4 screws on the back of the module.

Figure 3.8-2 Battery Return Module

Positive Battery Cable Connections

The battery return module has a shunt to measure the battery current and the load return modules do not. The Battery Return with Shunt has 4 sets of M8 threaded holes on 25.4 mm (1 in.) and 4.45 mm (1-3/4 in.) centers. Connect the battery return cables from the positive side of the battery string using the M8 hardware. Also connect the battery return cables from the positive side of the remote battery strings.

Battery Temperature Probe Installation

The optional temperature probe is used to monitor the battery string temperature. To get the most representative temperature measurement, the probe should be placed in contact with a battery cell that is centrally located. The probe should be placed directly in contact with the cell (not the frame surrounding the cell). Generally, the cell cover can be used; be careful not to allow the probe body to touch the terminals. Plug the connector end of the temperature probe into PL8 of the control unit backplane card. Route the cable as required

Magnum XS 450 Power System –48 VDC User’s Manual

Page 25

Image 30
Contents Magnum XS Vdc Power System User’s Manual Table of Contents Magnum XS 450 Power System -48 VDC User’s Manual Specifications Revision History Revision Date DescriptionSafety First General PrecautionsIntroduction General InformationMagnum XS 450 Power System -48 VDC User’s Manual How to Use This Manual Unpacking Equipment InstallationMechanical Installation Room / Location1 Door Clearance Dimensions Mounting VentilationAC Power Connections AC Kit with Three Phase SpreaderAC Line AC Neutral Earth Ground AC Kit with Phoenix Terminals Only AWGRectifier Shelf and Module Installation Rectifier Shelf Serial Communications Rectifier Shelf MechanicalRectifier AC Input Connections DC Distribution Module Installation Rectifier Module InstallationModule Selection Merlin Gerin 28 Circuit Breaker Module Installation 1 28 Circuit Breaker ModuleMerlin Gerin 12 Circuit Breaker Module Installation NH2 Fuse Module Installation Circuit Breaker Rating Ordering NumberDC Cabling General Instructions 3 NH2 Fuse ModuleDC Distribution Installation Circuit Breaker Installation2 Merlin Gerin 28 CB Module Installation Detail C60 C120 Total 4 CB Alarm Interface Board 28 circuit breaker module Installing a fuse in the NH2 Fuse Module DC Load Return Module InstallationBattery Installation Battery InstallationBattery Tray Installation Battery Disconnect Module InstallationNegative Battery Cable Connections 1 Battery Cable ConnectionsBattery Return Module Installation Positive Battery Cable ConnectionsBattery Temperature Probe Installation DC System Grounding Monitoring and Relay Output ConnectionsNetwork Management Card Relay Output Connections RJ45 Ethernet ConnectorSmart Cable DB9 Connection N/C-CExternal Alarm Input Connections Open Closed NO-C NC-CCommissioning Electrical InstallationBattery Visual and Safety Inspection Pre-Commissioning InspectionCommissioning Circuit Breaker/ Fuse Test Battery Temperature CompensationLVD Test User InputsFinal Inspection LVDOperation Technical DescriptionRectifier Management Battery Management DC DistributionAlarm Outputs Output Relays External Alarm Inputs Input RelaysCustomer Interface Board Equipment Preventive MaintenanceSystem Visual and Safety Inspection InspectionTest System Temperature Test Battery Current TestBattery Temperature Test Battery Preventive Maintenance Procedure Mechanical SpecificationsAC Input DCPM28HN54SH0 Rectifier EnvironmentalCompliance EMCAPC Worldwide Customer Support Limited Product Warranty

XS 450 -48 specifications

The American Power Conversion (APC) XS 450 -48 is a reliable and efficient power supply solution designed for critical applications requiring a consistent and stable power source. This solution is particularly beneficial for telecommunications, data centers, and industrial settings where power reliability is paramount.

One of the key features of the XS 450 -48 is its ability to deliver 450 watts of continuous power, ensuring that connected devices receive uninterrupted power supply. Its 48-volt output makes it ideal for telecom requirements, where 48V systems are standard. The unit provides a compact and space-saving design, making it suitable for installation in rack-mounted configurations, optimizing the utilization of valuable real estate in server rooms or equipment racks.

The XS 450 -48 utilizes advanced technologies that enhance its performance and reliability. It is equipped with an active power factor correction (PFC) system that significantly reduces harmonic distortion. This feature not only improves system efficiency but also complies with various regulations concerning power quality. Additionally, the power supply includes built-in over-voltage protection, over-current protection, and short-circuit protection, ensuring that both the power supply and the connected devices are safeguarded against electrical faults.

The unit is designed for high efficiency, often exceeding 90% under full load conditions. This not only reduces energy costs but also minimizes heat generation, contributing to a quieter operation environment. The XS 450 -48's intelligent thermal management system allows it to operate in a range of temperatures, making it highly versatile and adaptable to varying environmental conditions.

Furthermore, monitoring and management capabilities are integrated into the XS 450 -48 with optional external monitoring systems. These systems provide critical insights, allowing technicians to track real-time performance metrics, detect potential issues early on, and perform preventive maintenance.

In conclusion, the American Power Conversion XS 450 -48 stands out as a robust power supply solution that combines reliable performance, advanced protection features, and high efficiency. Its design caters to the specific needs of telecommunications and data centers, making it an indispensable asset for maintaining the uptime and integrity of critical systems. With its range of features and reliability, the XS 450 -48 continues to be a preferred choice among professionals in the field.