American Power Conversion XS 450 -48 user manual Magnum XS 450 Power System -48 VDC User’s Manual

Page 3

 

Relay Output Connections

27

 

External Alarm Input Connections

28

4

COMMISSIONING

29

 

4.1 PRE-COMMISSIONINGINSPECTION

29

 

Environment

29

 

Electrical Installation

29

 

Battery Visual and Safety Inspection

29

 

4.2

COMMISSIONING

30

 

Initial Set-up

30

 

AC Power Up

30

 

DC Power Up:

30

 

Rectifier Test:

30

 

Battery Power Up

30

 

LVD Test

31

 

Circuit Breaker/ Fuse Test:

31

 

User Inputs

31

 

Output Relay 1:

31

 

Battery Temperature Compensation

31

 

4.3

FINAL INSPECTION:

32

5

OPERATION

33

 

5.1

TECHNICAL DESCRIPTION

33

 

5.2

RECTIFIER MANAGEMENT

33

 

AC Input Power

33

 

DC Output Power

33

 

Rectifier alarms reporting

33

 

System Voltage Control

33

 

Rectifier Current

33

 

5.3

DC DISTRIBUTION

34

 

DC Distribution Module

34

 

DC Return Module

34

 

5.4

BATTERY MANAGEMENT

34

 

Battery Disconnect Module

34

 

Battery Return Module

34

 

Battery Shelves

34

 

Battery Cabinet

34

 

5.5 CUSTOMER INTERFACE BOARD

35

 

Alarm Outputs (Output Relays)

35

 

External Alarm Inputs (Input Relays)

35

6

PREVENTIVE MAINTENANCE

36

 

6.1

EQUIPMENT

36

 

6.2

INSPECTION

36

 

Environmental Inspection

36

 

System Visual and Safety Inspection

36

 

Battery Visual and Safety Inspection

36

 

6.3

TEST

37

 

System Voltage Test

37

 

Rectifier Current Test

37

 

Rectifier Current Share Test

37

 

System Current Test

37

 

Rectifier Alarm Test

37

Magnum XS 450 Power System –48 VDC User’s Manual

Page iii

Image 3
Contents Magnum XS Vdc Power System User’s Manual Table of Contents Magnum XS 450 Power System -48 VDC User’s Manual Specifications Revision Date Description Revision HistoryGeneral Precautions Safety FirstGeneral Information IntroductionMagnum XS 450 Power System -48 VDC User’s Manual How to Use This Manual Room / Location InstallationMechanical Installation Unpacking Equipment1 Door Clearance Dimensions Ventilation MountingAC Kit with Three Phase Spreader AC Power ConnectionsAC Line AC Neutral Earth Ground AWG AC Kit with Phoenix Terminals OnlyRectifier Shelf and Module Installation Rectifier Shelf Serial Communications Rectifier Shelf MechanicalRectifier AC Input Connections DC Distribution Module Installation Rectifier Module InstallationModule Selection 1 28 Circuit Breaker Module Merlin Gerin 28 Circuit Breaker Module InstallationMerlin Gerin 12 Circuit Breaker Module Installation Circuit Breaker Rating Ordering Number NH2 Fuse Module Installation3 NH2 Fuse Module DC Cabling General InstructionsCircuit Breaker Installation DC Distribution Installation2 Merlin Gerin 28 CB Module Installation Detail C60 C120 Total 4 CB Alarm Interface Board 28 circuit breaker module DC Load Return Module Installation Installing a fuse in the NH2 Fuse ModuleBattery Disconnect Module Installation Battery InstallationBattery Tray Installation Battery Installation1 Battery Cable Connections Negative Battery Cable ConnectionsBattery Return Module Installation Positive Battery Cable ConnectionsBattery Temperature Probe Installation DC System Grounding Monitoring and Relay Output ConnectionsNetwork Management Card N/C-C RJ45 Ethernet ConnectorSmart Cable DB9 Connection Relay Output ConnectionsOpen Closed NO-C NC-C External Alarm Input ConnectionsPre-Commissioning Inspection Electrical InstallationBattery Visual and Safety Inspection CommissioningCommissioning User Inputs Battery Temperature CompensationLVD Test Circuit Breaker/ Fuse TestLVD Final InspectionOperation Technical DescriptionRectifier Management DC Distribution Battery ManagementAlarm Outputs Output Relays External Alarm Inputs Input RelaysCustomer Interface Board Inspection Preventive MaintenanceSystem Visual and Safety Inspection EquipmentTest System Temperature Test Battery Current TestBattery Temperature Test Battery Preventive Maintenance Procedure Environmental SpecificationsAC Input DCPM28HN54SH0 Rectifier MechanicalEMC ComplianceAPC Worldwide Customer Support Limited Product Warranty

XS 450 -48 specifications

The American Power Conversion (APC) XS 450 -48 is a reliable and efficient power supply solution designed for critical applications requiring a consistent and stable power source. This solution is particularly beneficial for telecommunications, data centers, and industrial settings where power reliability is paramount.

One of the key features of the XS 450 -48 is its ability to deliver 450 watts of continuous power, ensuring that connected devices receive uninterrupted power supply. Its 48-volt output makes it ideal for telecom requirements, where 48V systems are standard. The unit provides a compact and space-saving design, making it suitable for installation in rack-mounted configurations, optimizing the utilization of valuable real estate in server rooms or equipment racks.

The XS 450 -48 utilizes advanced technologies that enhance its performance and reliability. It is equipped with an active power factor correction (PFC) system that significantly reduces harmonic distortion. This feature not only improves system efficiency but also complies with various regulations concerning power quality. Additionally, the power supply includes built-in over-voltage protection, over-current protection, and short-circuit protection, ensuring that both the power supply and the connected devices are safeguarded against electrical faults.

The unit is designed for high efficiency, often exceeding 90% under full load conditions. This not only reduces energy costs but also minimizes heat generation, contributing to a quieter operation environment. The XS 450 -48's intelligent thermal management system allows it to operate in a range of temperatures, making it highly versatile and adaptable to varying environmental conditions.

Furthermore, monitoring and management capabilities are integrated into the XS 450 -48 with optional external monitoring systems. These systems provide critical insights, allowing technicians to track real-time performance metrics, detect potential issues early on, and perform preventive maintenance.

In conclusion, the American Power Conversion XS 450 -48 stands out as a robust power supply solution that combines reliable performance, advanced protection features, and high efficiency. Its design caters to the specific needs of telecommunications and data centers, making it an indispensable asset for maintaining the uptime and integrity of critical systems. With its range of features and reliability, the XS 450 -48 continues to be a preferred choice among professionals in the field.