American Power Conversion XS 450 -48 user manual Specifications

Page 4

 

System Temperature Test

38

 

Battery Current Test

38

 

Battery Temperature Test

38

 

LVD Test

38

 

Battery Preventive Maintenance Procedure

39

 

6.4

FINAL INSPECTION:

39

7

SPECIFICATIONS

40

 

7.1

AC INPUT DCPM28HN54SH0 RECTIFIER

40

 

7.2

MECHANICAL

40

 

7.3

ENVIRONMENTAL

40

 

7.4

COMPLIANCE

41

8

APC WORLDWIDE CUSTOMER SUPPORT

42

9

LIMITED PRODUCT WARRANTY

43

Entire contents copyright © 2003 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC and the APC logo are trademarks or registered trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only

Magnum XS 450 Power System –48 VDC User’s Manual

Page iv

Image 4
Contents Magnum XS Vdc Power System User’s Manual Table of Contents Magnum XS 450 Power System -48 VDC User’s Manual Specifications Revision History Revision Date DescriptionSafety First General PrecautionsIntroduction General InformationMagnum XS 450 Power System -48 VDC User’s Manual How to Use This Manual Installation Mechanical InstallationUnpacking Equipment Room / Location1 Door Clearance Dimensions Mounting VentilationAC Power Connections AC Kit with Three Phase SpreaderAC Line AC Neutral Earth Ground AC Kit with Phoenix Terminals Only AWGRectifier Shelf and Module Installation Rectifier Shelf Mechanical Rectifier Shelf Serial CommunicationsRectifier AC Input Connections Rectifier Module Installation DC Distribution Module InstallationModule Selection Merlin Gerin 28 Circuit Breaker Module Installation 1 28 Circuit Breaker ModuleMerlin Gerin 12 Circuit Breaker Module Installation NH2 Fuse Module Installation Circuit Breaker Rating Ordering NumberDC Cabling General Instructions 3 NH2 Fuse ModuleDC Distribution Installation Circuit Breaker Installation2 Merlin Gerin 28 CB Module Installation Detail C60 C120 Total 4 CB Alarm Interface Board 28 circuit breaker module Installing a fuse in the NH2 Fuse Module DC Load Return Module InstallationBattery Installation Battery Tray InstallationBattery Installation Battery Disconnect Module InstallationNegative Battery Cable Connections 1 Battery Cable ConnectionsPositive Battery Cable Connections Battery Return Module InstallationBattery Temperature Probe Installation Monitoring and Relay Output Connections DC System GroundingNetwork Management Card RJ45 Ethernet Connector Smart Cable DB9 ConnectionRelay Output Connections N/C-CExternal Alarm Input Connections Open Closed NO-C NC-CElectrical Installation Battery Visual and Safety InspectionCommissioning Pre-Commissioning InspectionCommissioning Battery Temperature Compensation LVD TestCircuit Breaker/ Fuse Test User InputsFinal Inspection LVDTechnical Description OperationRectifier Management Battery Management DC DistributionExternal Alarm Inputs Input Relays Alarm Outputs Output RelaysCustomer Interface Board Preventive Maintenance System Visual and Safety InspectionEquipment InspectionTest Battery Current Test System Temperature TestBattery Temperature Test Battery Preventive Maintenance Procedure Specifications AC Input DCPM28HN54SH0 RectifierMechanical EnvironmentalCompliance EMCAPC Worldwide Customer Support Limited Product Warranty

XS 450 -48 specifications

The American Power Conversion (APC) XS 450 -48 is a reliable and efficient power supply solution designed for critical applications requiring a consistent and stable power source. This solution is particularly beneficial for telecommunications, data centers, and industrial settings where power reliability is paramount.

One of the key features of the XS 450 -48 is its ability to deliver 450 watts of continuous power, ensuring that connected devices receive uninterrupted power supply. Its 48-volt output makes it ideal for telecom requirements, where 48V systems are standard. The unit provides a compact and space-saving design, making it suitable for installation in rack-mounted configurations, optimizing the utilization of valuable real estate in server rooms or equipment racks.

The XS 450 -48 utilizes advanced technologies that enhance its performance and reliability. It is equipped with an active power factor correction (PFC) system that significantly reduces harmonic distortion. This feature not only improves system efficiency but also complies with various regulations concerning power quality. Additionally, the power supply includes built-in over-voltage protection, over-current protection, and short-circuit protection, ensuring that both the power supply and the connected devices are safeguarded against electrical faults.

The unit is designed for high efficiency, often exceeding 90% under full load conditions. This not only reduces energy costs but also minimizes heat generation, contributing to a quieter operation environment. The XS 450 -48's intelligent thermal management system allows it to operate in a range of temperatures, making it highly versatile and adaptable to varying environmental conditions.

Furthermore, monitoring and management capabilities are integrated into the XS 450 -48 with optional external monitoring systems. These systems provide critical insights, allowing technicians to track real-time performance metrics, detect potential issues early on, and perform preventive maintenance.

In conclusion, the American Power Conversion XS 450 -48 stands out as a robust power supply solution that combines reliable performance, advanced protection features, and high efficiency. Its design caters to the specific needs of telecommunications and data centers, making it an indispensable asset for maintaining the uptime and integrity of critical systems. With its range of features and reliability, the XS 450 -48 continues to be a preferred choice among professionals in the field.