Agilent Technologies 6611C, 6634B, 66332A SOURceDIGitalDATA, SOURceDIGitalFUNCtion, SOURceVOLTage

Page 59

Language Dictionary - 4

[SOURce:]DIGital:DATA

This command sets and reads the dc source digital control port when that port is configured for Digital I/O operation. The port has three signal pins and a digital ground pin. Pins 1 and 2 are output pins controlled by bits 0 and 1. Pin 3 is controlled by bit 2, and can be programmed to serve either as an input or an output. It normally serves as an output. Bit 2 must be programmed high to use pin 3 as an input. Pin 4 is the digital ground. The query returns the last programmed value in bits 0 and 1 and the value read at pin 3 in bit 2.

Program

Value

0

1

2

3

4

5

6

7

Bit Configuration

2

1

0

0

0

0

0

0

1

0

1

0

0

1

1

1

0

0

1

0

1

1

1

0

 

1

1

1

 

Pin Setting

 

4

3

2

1

GND Output

Lo

Lo

GND Output

Lo

Hi

GND Output

Hi

Lo

GND Output

Hi

Hi

GND

Intput

Lo

Lo

GND

Intput

Lo

Hi

GND

Intput

Hi

Lo

GND

Intput

Hi

Hi

Command Syntax

[SOURce]:DIGital:DATA[:VALue] <NRf>

Parameters

0 to 7

*RST Value

0

Examples

DIG:DATA 7

Query Syntax

[SOURce]:DIGital:DATA?

Returned Parameters

<NR1>

Related Commands

DIG:FUNC

[SOURce:]DIGital:FUNCtion

This command configures the dc source digital control port. The configuration setting is saved in non- volatile memory.

RIDFi

Configures the port for Remote Inhibit/Discrete Fault Interrupt operation

DIGio

Configures the port for Digital input/output operation (see DIG:DATA)

 

Command Syntax

[SOURce]:DIGital:FUNCtion <CRD>

 

Parameters

RIDFi DIGio

 

Examples

DIG:FUNC DIG

 

Query Syntax

[SOURce]:DIGital:FUNC?

 

Returned Parameters

<CRD>

 

Related Commands

DIG:DATA

[SOURce:]VOLTage

This command sets the output voltage level of the dc source.

Command Syntax

[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]<NRf+>

Parameters

see Table 4-3

 

Default Suffix

V (volts)

 

*RST Value

0

 

Examples

VOLT 2

VOLTAGE:LEVEL 200 MV

Query Syntax

[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?

Returned Parameters

<NR3>

 

Related Commands

VOLT:TRIG

 

59

Image 59
Contents Programming Guide Printing History Safety GuidelinesTable of Contents Internally Triggered Measurements Language DictionaryOutput Commands Example Programs Error MessagesScpi Conformance Information Compatibility LanguageDocumentation Summary About this GuideScpi References External ReferencesGpib References System Requirements VXIplug&play Power Products Instrument DriversDownloading and Installing the Driver Supported ApplicationsGpib Address Accessing Online HelpGpib Capabilities of the DC Source RS-232 Capabilities of the DC SourceBaud Rate RS-232 Flow ControlRS-232 Programming Example Boldface font RS-232 TroubleshootingIntroduction to Scpi Conventions Used in This GuideMultiple Commands in a Message Types of Scpi CommandsMoving Among Subsystems Including Common CommandsUsing Queries Types of Scpi MessagesMessage Unit Separator Query IndicatorMessage Unit HeadersResponse Data Types Scpi Data FormatsNumerical Data Formats Suffixes and MultipliersUsing Device Clear Scpi Command CompletionPage Enabling the Output Power-on InitializationIntroduction Programming the OutputMaximum Current Output VoltageOutput Current Maximum VoltageOutput Trigger System Model Setting the Voltage or Current Trigger LevelsTriggering Output Changes Scpi Triggering NomenclatureGenerating Triggers Initiating the Output Trigger SystemDC Measurements Making MeasurementsVoltage and Current Measurements Current Ranges RMS Measurements Agilent 66312A, 66332A OnlySequence Form Alias SEQuence2 ACQuire Internally Triggered MeasurementsMeasurement Trigger System Model BUS Generating Measurement Triggers Agilent 66312A, 66332A OnlyTrigger Commands Used to Measure Output Pulses Pulse Measurement Queries Measuring Output Pulses Agilent 66312A, 66332A OnlyCurrent Detector Multiple Measurements Agilent 66312A, 66332A Only Controlling Measurement SamplesVarying the Voltage or Current Sampling Rate Pre-event and Post-event Triggering Pulse Measurement Example Agilent 66312A, 66332A onlyOption Base Programming the Status Registers Power-On ConditionsOperation Status Group Status Byte Register Questionable Status GroupStandard Event Status Group RQS Bit Determining the Cause of a Service InterruptServicing Operation Status and Questionable Status Events MSS BitRemote Inhibit RI Inhibit/Fault IndicatorMonitoring Both Phases of a Status Transition Discrete Fault Indicator DFIPin Using the Inhibit/Fault Port as a Digital I/OBit Weight DFI Programming ExamplePage Language Dictionary Subsystem CommandsSubsystem Commands Syntax ALC DFISubsystem Commands Syntax Output Programming Parameters Common CommandsCommon Commands Syntax Programming ParametersCALibrateCURRentMEASureLOWRange Calibration CommandsCALibrateCURRent CALibrateCURRentNEGativeCALibrateLEVel CALibratePASSwordCommand Syntax CALibrateSAVE Parameters None Examples CALibrateDATAQuery Syntax CALibrateSTATe? CALibrateSTATeCALibrateVOLTage CALibrateVOLTagePROTectionQuery Syntax Measurement CommandsMEASureARRayCURRent? FETChARRayCURRent? MEASureARRayVOLTage? FETChARRayVOLTage?FETChCURRent? applies to Agilent 66312A, 66332A Only MEASureCURRent? FETChCURRent?MEASureCURRentACDC? FETChCURRentACDC? MEASureCURRentHIGH? FETChCURRentHIGH?MEASureCURRentMINimum? FETChCURRentMINimum? MEASureCURRentLOW? FETChCURRentLOW?MEASureCURRentMAXimum? FETChCURRent MAXimum? FETChVOLTage? applies to Agilent 66312A, 66332A Only MEASureVOLTage? FETChVOLTage?MEASureVOLTageACDC? FETChVOLTageACDC? MEASureVOLTageHIGH? FETChVOLTageHIGH?MEASureVOLTageMINimum? FETChVOLTageMINimum? MEASureVOLTageLOW? FETChVOLTageLOW?MEASureVOLTageMAXimum? FETChVOLTageMAXimum? Returned Parameters NR3 SENSeCURRentRANGeSENSeCURRentDETector Unit a amperes *RST Value MAX high rangeSENSeSWEepTINTerval SENSeFUNCtionSENSeSWEepOFFSetPOINts SENSeSWEepPOINtsReturned Parameters CRD SENSeWINDowHANNing RECTangularOUTPutDFISOURce Output CommandsOUTPut OUTPutDFIOUTPutPROTectionCLEar OUTPutPROTectionDELayOUTPutPONSTATe Query Syntax OUTPputRELayPOLarity? OUTPutRELayOUTPutRELayPOLarity OUTPutRIMODESOURceCURRentPROTectionSTATe Default SuffixSOURceCURRent SOURceCURRentTRIGgerQuery Syntax SOURceDIGitalDATA? SOURceDIGitalDATASOURceDIGitalFUNCtion SOURceVOLTageAgilent 66332A, 6631B, 6632B, 6633B and 6634B Only SOURceVOLTageALCBANDwidth? SOURceVOLTageALCBWIDth?SOURceVOLTageTRIGger SOURceVOLTagePROTectionSTATusOPERationCONDition? Status CommandsSTATusPRESet STATusOPERation?STATusOPERationNTR STATusOPERationPTR STATusOPERationENABleQuery Syntax STATusOPERationENABle? Parameters Preset ValueSTATusQUEStionableCONDition? STATusQUEStionableENABleSTATusQUEStionable? STATQUESNTR?STATQUESPTR? Command Syntax *CLS Parameters NoneSTATusQUEStionableNTR STATusQUEStionablePTR CLSOPC Bit Configuration of Standard Event Status Enable RegisterESE ESR?Example PSCSRE PSC onNR1 register binary value Bit Configuration of Status Byte RegisterSTB? WAIDISPlayTEXT System CommandsDISPlay DISPlayMODEParameters none Returned Parameters NR2 SYSTemERRor?SYSTemLANGuage SYSTemVERSion?IDN? SYSTemLOCalSYSTemREMote SYSTemRWLockRST Command Syntax RCL NRf Parameters ExampleOPT? RCLTST? RST SettingsCommand Syntax SAV NRf Parameters Example SAVINITiateCONTinuousSEQuence1 INITiateCONTinuousNAME Trigger CommandsABORt INITiateSEQuence INITiateNAMEAbor Currtrig Init *TRG Volttrig TRIGgerTRIGgerSOURce TRIGgerSEQuence2 TRIGgerACQuireTRIGSEQ2COUNCURR 5 Trigacqcouncurr TRIGgerSEQuence2COUNtCURRent TRIGgerACQuireCOUNtCURRentTRIGgerSEQuence2COUNtVOLTage TRIGgerACQuireCOUNtVOLTage Parameters RST Value ExamplesTRIGSEQ2HYSTCURR TRIGSEQ2LEVVOLT TRIGSEQ2HYSTVOLT TRIGSEQ2LEVCURRTRIGSEQ2LEVCURR TRIGSEQ2HYSTVOLT TRIGgerSEQuence2LEVelCURRent TRIGgerACQuireLEVelCURRentTRIGgerSEQuence2LEVelVOLTage TRIGgerACQuireLEVelVOLTage TRIGSEQ2LEVVOLT TRIGSEQ2HYSTCURRTRIGSEQ2SLOPVOLT TRIGgerSEQuence2SLOPeCURRent TRIGgerACQuireSLOPeCURRentTRIGgerSEQuence2SLOPeVOLTage TRIGgerACQuireSLOPeVOLTage TRG Parameters None Related CommandsTRIGgerSEQuence2SOURce TRIGgerACQuireSOURce TRIGgerSEQuence1DEFine TRIGgerSEQuence2DEFinePage Scpi Version Scpi Confirmed CommandsNon-SCPI Commands Page Command Setting Table B-1. COMPatibility Power-on Settings CommandASTS? CLR Table B-2. COMPatibility Commands CompatibilityERR? FAULT? ID? IOUT? Similar Scpi CommandTable B-2. COMPatibility Commands Description Similar Scpi Compatibility CommandError Table B-2. COMPatibility CommandsCompatibility Description Command These commands determine the conditions that will set bitsFAU Norm Fast INH ERR UNR +CCRQS ERR RDY Page Bit Set Error Number Error Code Error Type Error Number ListTable C-1. Error Numbers Error Number Page National Instruments Gpib Driver Assigning the Gpib Address in ProgramsTypes of DOS Drivers Agilent 82335A DriverBasic Controllers Error HandlingExample Programs D Call IBCLRPS% Example 2. IBM Controller Using National InterfaceCODES$=*CLS Option Base Example 3. Controller Using BasicIndex 100 IndexScpi 101102 Manual Updates
Related manuals
Manual 82 pages 25.5 Kb Manual 83 pages 60.43 Kb

6613C, 66312A, 6631B, 6611C, 6614C specifications

Agilent Technologies, a leader in electronic test and measurement solutions, offers a range of power supplies designed to meet various application needs. Notable models include the 6632B, 6634B, 66332A, 6633B, and 6612C. Each of these units provides unique features and technologies that cater to researchers, engineers, and technicians in the industry.

The Agilent 6632B is a single-output DC power supply that delivers up to 30V and 3A. It is known for its excellent load regulation and low noise, making it ideal for sensitive electronic testing. The model includes built-in voltage and current measurement capabilities, allowing users to monitor output conditions in real time. The 6632B is commonly used in laboratory environments, educational institutions, and manufacturing lines.

Moving to the 6634B, this model offers dual-output capabilities with a maximum output of 30V and 6A. This versatility enables simultaneous powering of two different devices or circuit sections. It also features parallel and series operation options, allowing users to create a custom power supply configuration for specific applications. With a programmable interface, the 6634B simplifies test automation, ensuring efficiency in extensive testing scenarios.

The Agilent 66332A stands out with its precision and high performance. This power supply provides three outputs—two programmable and one fixed—yielding flexible power configurations. Its intuitive user interface allows easy adjustment of voltage and current settings. The device is equipped with extensive protection features to safeguard both the power supply and the connected load against faults. It is an excellent choice for complex testing setups that require reliable power.

The 6633B model offers a high-performance power supply with dual outputs, similar to the 6634B but with enhanced specifications. It can provide up to 40V and 2A per channel, delivering precision for demanding applications. This model is particularly suited for industries focused on high-reliability applications, such as telecommunications and aerospace.

Lastly, the Agilent 6612C is a compact and lightweight power supply providing single-output up to 60V and 2A. This model is designed for simplicity and ease of use, making it an excellent choice for portable applications. The 6612C’s unique characteristics include a compact design and user-friendly controls, which facilitate operation in field settings.

In summary, Agilent Technologies’ power supply models—6632B, 6634B, 66332A, 6633B, and 6612C—offer an array of features that cater to a wide range of testing and research needs, ensuring reliable power delivery in various contexts.