Agilent Technologies 6633B, 6634B STATusOPERationENABle, STATusOPERationNTR STATusOPERationPTR

Page 62

4 - Language Dictionary

STATus:OPERation:ENABle

This command and its query set and read the value of the Operational Enable register. This register is a mask for enabling specific bits from the Operation Event register to set the operation summary bit (OPER) of the Status Byte register. This bit (bit 7) is the logical OR of all the Operatonal Event register bits that are enabled by the Status Operation Enable register.

Command Syntax

STATus:OPERation:ENABle<NRf>

Parameters

0 to 32727

Preset Value

0

Examples

STAT:OPER:ENAB 1312STAT:OPER:ENAB 1

 

STATUS:OPERATION:ENABLE?

Query Syntax

STATus:OPERation:ENABle?

Returned Parameters

<NR1> (register value)

Related Commands

STAT:OPER:EVEN

STATus:OPERation:NTR

STATus:OPERation:PTR

These commands set or read the value of the Operation NTR (Negative-Transition) and PTR (Positive- Transistion) registers. These registers serve as polarity filters between the Operation Enable and Operation Event registers to cause the following actions:

υWhen a bit in the Operation NTR register is set to 1, then a 1-to-0 transition of the corresponding bit in the Operation Condition register causes that bit in the Operation Event register to be set.

υWhen a bit of the Operation PTR register is set to 1, then a 0-to-1 transition of the corresponding bit in the Operation Condition register causes that bit in the Operation Event register to be set.

υIf the same bits in both NTR and PTR registers are set to 1, then any transition of that bit at the Operation Condition register sets the corresponding bit in the Operation Event register.

υIf the same bits in both NTR and PTR registers are set to 0, then no transition of that bit at the Operation Condition register can set the corresponding bit in the Operation Event register.

Command Syntax

STATus:OPERtion:NTRansition<NRf>

 

STATus:OPERtion:PTRansition<NRf>

Parameters

0 to 32727

 

Preset Value

NTR register = 0; PTR register = 32727

Examples

STAT:OPER:NTR 32

STAT:OPER:PTR 1312

Query Syntax

STAT:OPER:NTR?

STAT:OPER:PTR?

Returned Parameters

<NR1> (register value)

 

Related Commands

STAT:OPER:ENAB

 

62

Image 62
Contents Programming Guide Safety Guidelines Printing HistoryTable of Contents Language Dictionary Internally Triggered MeasurementsOutput Commands Compatibility Language Error MessagesScpi Conformance Information Example ProgramsAbout this Guide Documentation SummaryScpi References External ReferencesGpib References Supported Applications VXIplug&play Power Products Instrument DriversDownloading and Installing the Driver System RequirementsRS-232 Capabilities of the DC Source Accessing Online HelpGpib Capabilities of the DC Source Gpib AddressBaud Rate RS-232 Flow ControlRS-232 Programming Example Conventions Used in This Guide RS-232 TroubleshootingIntroduction to Scpi Boldface fontTypes of Scpi Commands Multiple Commands in a MessageTypes of Scpi Messages Including Common CommandsUsing Queries Moving Among SubsystemsHeaders Query IndicatorMessage Unit Message Unit SeparatorSuffixes and Multipliers Scpi Data FormatsNumerical Data Formats Response Data TypesScpi Command Completion Using Device ClearPage Programming the Output Power-on InitializationIntroduction Enabling the OutputMaximum Voltage Output VoltageOutput Current Maximum CurrentScpi Triggering Nomenclature Setting the Voltage or Current Trigger LevelsTriggering Output Changes Output Trigger System ModelInitiating the Output Trigger System Generating TriggersDC Measurements Making MeasurementsVoltage and Current Measurements RMS Measurements Agilent 66312A, 66332A Only Current RangesSequence Form Alias SEQuence2 ACQuire Internally Triggered MeasurementsMeasurement Trigger System Model Generating Measurement Triggers Agilent 66312A, 66332A Only BUSTrigger Commands Used to Measure Output Pulses Pulse Measurement Queries Measuring Output Pulses Agilent 66312A, 66332A OnlyCurrent Detector Multiple Measurements Agilent 66312A, 66332A Only Controlling Measurement SamplesVarying the Voltage or Current Sampling Rate Pulse Measurement Example Agilent 66312A, 66332A only Pre-event and Post-event TriggeringOption Base Power-On Conditions Programming the Status RegistersOperation Status Group Status Byte Register Questionable Status GroupStandard Event Status Group MSS Bit Determining the Cause of a Service InterruptServicing Operation Status and Questionable Status Events RQS BitDiscrete Fault Indicator DFI Inhibit/Fault IndicatorMonitoring Both Phases of a Status Transition Remote Inhibit RIDFI Programming Example Using the Inhibit/Fault Port as a Digital I/OBit Weight PinPage Subsystem Commands Language DictionarySubsystem Commands Syntax DFI ALCSubsystem Commands Syntax Programming Parameters Common CommandsCommon Commands Syntax Output Programming ParametersCALibrateCURRentNEGative Calibration CommandsCALibrateCURRent CALibrateCURRentMEASureLOWRangeCALibrateDATA CALibratePASSwordCommand Syntax CALibrateSAVE Parameters None Examples CALibrateLEVelCALibrateVOLTagePROTection CALibrateSTATeCALibrateVOLTage Query Syntax CALibrateSTATe?MEASureARRayVOLTage? FETChARRayVOLTage? Measurement CommandsMEASureARRayCURRent? FETChARRayCURRent? Query SyntaxMEASureCURRentHIGH? FETChCURRentHIGH? MEASureCURRent? FETChCURRent?MEASureCURRentACDC? FETChCURRentACDC? FETChCURRent? applies to Agilent 66312A, 66332A OnlyMEASureCURRentMINimum? FETChCURRentMINimum? MEASureCURRentLOW? FETChCURRentLOW?MEASureCURRentMAXimum? FETChCURRent MAXimum? MEASureVOLTageHIGH? FETChVOLTageHIGH? MEASureVOLTage? FETChVOLTage?MEASureVOLTageACDC? FETChVOLTageACDC? FETChVOLTage? applies to Agilent 66312A, 66332A OnlyMEASureVOLTageMINimum? FETChVOLTageMINimum? MEASureVOLTageLOW? FETChVOLTageLOW?MEASureVOLTageMAXimum? FETChVOLTageMAXimum? Unit a amperes *RST Value MAX high range SENSeCURRentRANGeSENSeCURRentDETector Returned Parameters NR3SENSeSWEepPOINts SENSeFUNCtionSENSeSWEepOFFSetPOINts SENSeSWEepTINTervalRECTangular SENSeWINDowHANNing Returned Parameters CRDOUTPutDFI Output CommandsOUTPut OUTPutDFISOURceOUTPutPROTectionCLEar OUTPutPROTectionDELayOUTPutPONSTATe OUTPutRIMODE OUTPutRELayOUTPutRELayPOLarity Query Syntax OUTPputRELayPOLarity?SOURceCURRentTRIGger Default SuffixSOURceCURRent SOURceCURRentPROTectionSTATeSOURceVOLTage SOURceDIGitalDATASOURceDIGitalFUNCtion Query Syntax SOURceDIGitalDATA?SOURceVOLTagePROTection SOURceVOLTageALCBANDwidth? SOURceVOLTageALCBWIDth?SOURceVOLTageTRIGger Agilent 66332A, 6631B, 6632B, 6633B and 6634B OnlySTATusOPERation? Status CommandsSTATusPRESet STATusOPERationCONDition?Parameters Preset Value STATusOPERationENABleQuery Syntax STATusOPERationENABle? STATusOPERationNTR STATusOPERationPTRSTATusQUEStionableCONDition? STATusQUEStionableENABleSTATusQUEStionable? CLS Command Syntax *CLS Parameters NoneSTATusQUEStionableNTR STATusQUEStionablePTR STATQUESNTR?STATQUESPTR?ESR? Bit Configuration of Standard Event Status Enable RegisterESE OPCPSC on PSCSRE ExampleWAI Bit Configuration of Status Byte RegisterSTB? NR1 register binary valueDISPlayMODE System CommandsDISPlay DISPlayTEXTSYSTemVERSion? SYSTemERRor?SYSTemLANGuage Parameters none Returned Parameters NR2SYSTemRWLock SYSTemLOCalSYSTemREMote IDN?RCL Command Syntax RCL NRf Parameters ExampleOPT? RSTSAV RST SettingsCommand Syntax SAV NRf Parameters Example TST?INITiateSEQuence INITiateNAME Trigger CommandsABORt INITiateCONTinuousSEQuence1 INITiateCONTinuousNAMETRIGgerSEQuence2 TRIGgerACQuire TRIGgerTRIGgerSOURce Abor Currtrig Init *TRG VolttrigParameters RST Value Examples TRIGgerSEQuence2COUNtCURRent TRIGgerACQuireCOUNtCURRentTRIGgerSEQuence2COUNtVOLTage TRIGgerACQuireCOUNtVOLTage TRIGSEQ2COUNCURR 5 TrigacqcouncurrTRIGSEQ2HYSTVOLT TRIGSEQ2LEVCURR TRIGSEQ2HYSTCURR TRIGSEQ2LEVVOLTTRIGSEQ2LEVVOLT TRIGSEQ2HYSTCURR TRIGgerSEQuence2LEVelCURRent TRIGgerACQuireLEVelCURRentTRIGgerSEQuence2LEVelVOLTage TRIGgerACQuireLEVelVOLTage TRIGSEQ2LEVCURR TRIGSEQ2HYSTVOLTTRIGSEQ2SLOPVOLT TRIGgerSEQuence2SLOPeCURRent TRIGgerACQuireSLOPeCURRentTRIGgerSEQuence2SLOPeVOLTage TRIGgerACQuireSLOPeVOLTage TRIGgerSEQuence1DEFine TRIGgerSEQuence2DEFine Parameters None Related CommandsTRIGgerSEQuence2SOURce TRIGgerACQuireSOURce TRGPage Scpi Version Scpi Confirmed CommandsNon-SCPI Commands Page Table B-1. COMPatibility Power-on Settings Command Command SettingSimilar Scpi Command Table B-2. COMPatibility Commands CompatibilityERR? FAULT? ID? IOUT? ASTS? CLRCompatibility Command Table B-2. COMPatibility Commands Description Similar ScpiThese commands determine the conditions that will set bits Table B-2. COMPatibility CommandsCompatibility Description Command ErrorFAU Norm Fast INH ERR UNR +CCRQS ERR RDY Page Error Number List Bit Set Error Number Error Code Error TypeTable C-1. Error Numbers Error Number Page Agilent 82335A Driver Assigning the Gpib Address in ProgramsTypes of DOS Drivers National Instruments Gpib DriverError Handling Basic ControllersExample Programs D Example 2. IBM Controller Using National Interface Call IBCLRPS%CODES$=*CLS Example 3. Controller Using Basic Option BaseIndex Index 100101 Scpi102 Manual Updates
Related manuals
Manual 82 pages 25.5 Kb Manual 83 pages 60.43 Kb

6613C, 66312A, 6631B, 6611C, 6614C specifications

Agilent Technologies, a leader in electronic test and measurement solutions, offers a range of power supplies designed to meet various application needs. Notable models include the 6632B, 6634B, 66332A, 6633B, and 6612C. Each of these units provides unique features and technologies that cater to researchers, engineers, and technicians in the industry.

The Agilent 6632B is a single-output DC power supply that delivers up to 30V and 3A. It is known for its excellent load regulation and low noise, making it ideal for sensitive electronic testing. The model includes built-in voltage and current measurement capabilities, allowing users to monitor output conditions in real time. The 6632B is commonly used in laboratory environments, educational institutions, and manufacturing lines.

Moving to the 6634B, this model offers dual-output capabilities with a maximum output of 30V and 6A. This versatility enables simultaneous powering of two different devices or circuit sections. It also features parallel and series operation options, allowing users to create a custom power supply configuration for specific applications. With a programmable interface, the 6634B simplifies test automation, ensuring efficiency in extensive testing scenarios.

The Agilent 66332A stands out with its precision and high performance. This power supply provides three outputs—two programmable and one fixed—yielding flexible power configurations. Its intuitive user interface allows easy adjustment of voltage and current settings. The device is equipped with extensive protection features to safeguard both the power supply and the connected load against faults. It is an excellent choice for complex testing setups that require reliable power.

The 6633B model offers a high-performance power supply with dual outputs, similar to the 6634B but with enhanced specifications. It can provide up to 40V and 2A per channel, delivering precision for demanding applications. This model is particularly suited for industries focused on high-reliability applications, such as telecommunications and aerospace.

Lastly, the Agilent 6612C is a compact and lightweight power supply providing single-output up to 60V and 2A. This model is designed for simplicity and ease of use, making it an excellent choice for portable applications. The 6612C’s unique characteristics include a compact design and user-friendly controls, which facilitate operation in field settings.

In summary, Agilent Technologies’ power supply models—6632B, 6634B, 66332A, 6633B, and 6612C—offer an array of features that cater to a wide range of testing and research needs, ensuring reliable power delivery in various contexts.