Reactivity Data

Stability: Stable

Polymerization: Will not occur.

Hazardous Decomposition Products: Thermal decom- position may result in release of oxides of carbon and nitrogen.

Temperature: Do not expose to temperatures above 200°C (392°F).

Incompatibility: Avoid exposure to strong oxidizers.

Spill Cleanup and Disposal

Spill Cleanup

Small Spills

1.Remove sources of ignition.

2.Clean up spill with wet cloth.

Large Spills

1.Remove sources of ignition.

2.Wear protective gear: respirator, rubber gloves, goggles (see below)

3.Clean up spill with scoop, being careful not to generate a lot of dust.

Waste Disposal: Follow appropriate federal, state and local regulations.

Safe Handling and Use

Respiratory Protection: Not normally required. For

large spills, use NIOSH-approved full face-piece respirator with HEPA cartridge during cleanup.

Protective Gloves and/or Eye Protection: Not normally required. For large spills, use rubber gloves and chemical worker’s goggles during cleanup.

Ventilation: Outside of normal ventilation, not normally required.

Other Protective Equipment and/or Hygienic Prac- tices: None

Special Precautions

Precautions for Handling or Storage: Protect from high heat. Avoid making dust.

Other Precautions: None

The information contained in this MSDS is based on data considered accurate; however, no warranty is expressed or implied regarding the accuracy of these data or the results to be obtained from the use thereof. Vendor assumes no responsibility for injury to vendee or third person party proximately caused by the product if reasonable safety procedures are not adhered to as stipulated in the MSDS. Furthermore, vendor assumes no responsibility for injury to vendee or third person party proximately caused by abnormal use of the product even if reasonable safety procedures are followed. Additionally, vendee assumes the risk of his use of the product.

June 1997

Image 108
Contents Handbook Okidata Federal Communications Commission Requirements for End Users FCC Telephone Consumer Protection Act Of5356fm.pm6 98, 519 PM Industry Canada Radio Interference Statement Safety Toner Cartridge Image Drum Unit Handling Direct Access ManuallyContents Faxing Advanced Operations Fax Reports Index Introduction Order Number Introduction Component Identification What You Should ReceiveComponents Jack for connecting to an outside telephone line Control Panel Control Panel Keys and Indicators Introduction Introduction One Touch Keys available Introduction Signal Tones Installation Setting Up Your Okifax 5300 Plus/5600 Plus Install the Toner Cartridge Connect to the Telephone Line Okifax Connect Power Time 235 PM 3CLOCK Adjustment Setting the Answering Mode Setting the Fax Identification 4SYSTEM Data PRG Setting the Language Connecting to a PBX Copying Using the Manual Paper Feeder Copying Faxing Dial Directories Faxing Dial DirectoriesOne Touch Parameters Chain Dialing Programming Groups Gramming Faxing Basic Operations Loading Documents Your documents are now ready for faxing or copying Shortcut Fax Number Programming Receiving Faxes Manually Receiving Faxes in Memory Power Failures and Memory Lift the handset and press the Hook V Request key Faxing Advanced Operations Okifax 5600 Plus Press the Yes key Cation Cancel Sending a Confidential Fax 5PERSONAL BOX PRG Changing Your Password or Closing a Mailbox Sonal BOX Relay Password Enter Relay PasswordRemote List NO. Enter Remote List noBulletin Poll Select Location Bulltin Poll What You Can Do While Making Copies Customizing Okifax 5300 Plus/ 5600 Plus STD/NORMAL Distinctive RING, SET Setup FAX Ring Call FAX Number NOW Not Used Changing Your User Function Settings 2DIAL Parameter Service Function Settings Fax Reports Printing Reports Broadcast Confirmation Report MCF Current dial parameter settings Problem Solving Push the buttons on the side of the copy stacker until Problem Solving Printing a Cleaning Problem Solving Close the document table Change Drum Soon Message Problem Solving 0213 FAX Document JAM Confirm Paper Size Error Problem Checklist Problem Solving Problem Solving Consumer relations Limited Warranty Okidata Service Locations Mexico Specifications ITU-T G3CategorySpecifications Environmental Index Auto StartBusy Tone Detect Dial Prefix Incoming Ring ONE Touch Param PBX Line TIME/DATE Print TSI/CSIMaterial Safety Data Sheet Appearance and odor Black granules, no odor Small Spills