4.Use the following tables to set the DIP switches. Numbers starting with 1 are in the first set, and numbers starting with 2 are in the second (only for
TM-T85 DIP-Switch Functions
DIP Switch Set 1
Switch | Function | ON | OFF |
|
|
|
|
Data reception error | Ignored | Prints”?” | |
|
|
|
|
Receive buffer capacity | 45 bytes | 4K bytes | |
|
|
|
|
Handshaking | XON/XOFF | DTR/DSR | |
|
|
|
|
Word length | 7 bits | 8 bits | |
|
|
|
|
Parity check | Yes | No | |
|
|
|
|
Parity selection | Even | Odd | |
|
|
|
|
See Transmission Speeds table below |
| ||
|
| ||
| |||
|
|
| |
|
|
|
|
Transmission Speeds
Speed in Bits per Second | SW | SW |
|
|
|
2400 | ON | ON |
|
|
|
4800 | OFF | ON |
|
|
|
9600 | ON | OFF |
|
|
|
19200 | OFF | OFF |
|
|
|
DIP Switch Set 2
Switch | Function | ON | OFF | |
|
|
|
| |
Handshaking (BUSY | Receive buffer full | Off line or receive | ||
condition) | buffer full | |||
|
| |||
|
|
|
| |
Selects print density | See Print Density Table below | |||
| ||||
|
|
| ||
|
|
|
|