8.2Setting transfer properties
On the desktop, press the icon
Select PN/IE under Channel.
Select the Enable Transfer check box and the Remote Control check box.
The settings in the Transfer Settings window have nothing to do with the connection settings in the WinCC project.
This means, for example, that data can be transferred between the TP700 Panel and WinCC using the Ethernet interface, and that communication between the panel and the SIMATIC S7 controller can take place using the MPI interface.
In our example, data is transferred between the TP700 Panel and WinCC and communication takes place between the panel and the SIMATIC S7 controller by means of the Ethernet interface.
To set the IP address on the panel, click Properties to edit or check the network settings.
To set the MPI or PROFIBUS address on the panel, click Properties to edit or check the bus settings after the selection of the interface.
Select the PN/IE interface.
Click OK to confirm.