1.3 S-LS overview

The S-LS (TOSLINE-S20 Loader System) on a personal computer (PC) monitors station conditions, reads/writes control data, and sets up parameters. The transmission parameters set by S-LS is stored in the S20LP-station's built-in EEPROM.

Connection between S-LS and S20LP-station is made by an loader cable, that is the same cable as for T-PDS.

The following are the details of the menu. Select an intended station in the Station Connection Diagram window for display and specify the window in the menu or the toolbar.

[File]

[Display Scan Address List] [Display Station Down Information] [Save Files All Station’s Information] [Exit]

Displays the Scan Address List window.

Displays Down Information when the local station is downed. Saves the setup information of all stations in the file. Terminates the application.

[Menu]

[Setting Information]

Displays the Setting Information window.

[Data Access]

Displays the Data Access window.

[RAS Information]

 

[Online Map]

Displays the Online Map window.

[Scan Healthy Map]

Displays the Scan Healthy Map window.

[Loop Map]

Displays the Loop Map window.

[Station Status]

Displays the Station Status window.

[Station Down Information]

Displays the Station Down Information.

[RAS Counter Information]

Displays the RAS Counter Information

[Online/Standby Request]

Displays the Online/Standby Request window.

[Test Request]

Displays the Test Request window.

[Option]

[Station Display Position]

 

[Registration]

Registers the display positions of the stations rearranged.

[Display]

Reflects the display positions of the registered stations in the window.

[Normal]

Displays the stations rearranged in the ascending order of smaller display

 

position numbers.

[Communication Environment Setting] Displays the Communication Environment Setting window.

[Window]

[Display Small Size]Displays the Station Connection Diagram in small size.

[Help]

[Contents]

Displays the Help window.

[Key Word Search]

Displays the Retrieve window in Help.

[Version Information]

Displays the information of the application version.

9

Image 10
Contents T2N/T3H stations Important Information Preface Contents System configuration Introduction to S20LP∙ Overview Station hardwareT2N include of S20LP Port SN325 SN325S20LP port for T2N PU245N ∙ Status LEDsFor SN325 ∙ Reset switch only SN325 ∙ Station number setting switches∙ Transmission cable connectors ∙ Loader portLS overview Menu⎯ 10 ⎯ S20LP system specifications SpecificationsS20LP-station specifications Scan transmission overview Setting the data send block by S-LS Allocation and network assignment by T-PDSStation number setting Setting for data linkageSettings on T-PDS Link PDS screen example Block Send Receive ⎯ 18 ⎯ Global ⎯ 20 ⎯ Settings on S-LS ⎯ 22 ⎯ ⎯ 23 ⎯ ⎯ 24 ⎯ ∙ Scan Transmission ∙ Scan Access∙ Start with Standby mode ∙ Message Transmission∙ Target Scan Time Data linkage example ∙ Settings on T-PDS Setting on S-LS LS setting screen 2 for STN #2 Cable connections ∙ Station down RAS functionBehavior in trouble ∙ Transmission cable breakageAt initialization at power on Self-diagnostic functionDuring operation SN325 LED indicationT2N RAS information monitored in T2N/T3H Station status Online mapStandby map Loop map Only T2NRAS information monitored on S-LS Number 1-64 on the screen shows the Station numberSelf Station Station No.01 Offline Select the Station Number Click the Status Display Possible error message are as follows Station down informationInstruction format Instruction SpecificationExpanded data transfer instruction FunctionParameter and construction Transfer parameter tableSample program ∙ OperationRemarks Computer link protocol Message transmissionMessage transmission PC link protocol∙ Send Transfer parameters a CMDStatus B TermSTS Status Meaning Detailed Information Send completion status PC link protocol transmission Data write Transfer parametersRID Status See 7.3 5 for details on bits C, D, E, and F Important itemsXW/YW PC link protocol transmission Data read ⎯ 57 ⎯ SW067 Write enabled PC link protocol transmission program RemarksLength END Appendix Scan cycle⎯ 63 ⎯ PDS remote programming PDS Setup options screen