Toshiba S20LP instruction manual ⎯ 23 ⎯

Page 24

6 F 3 B 0 3 5 6

Select the "Station Number" of the connected S20LP-station. Select the "Scan Transmission" and specify the "data send block(s)". The "data send block" is specified by entering the starting address (Send Starting Address 1/2) and the size (Number of Send Words 1/2). Up to two "data send blocks" can be specified. If "data send block 2" is not used, enter 0 both for Send Starting Address 2 and Number of Send Words 2. The maximum size of send words is Number of Send Words 1 and 2, total 1024 words.

23

Image 24
Contents T2N/T3H stations Important Information Preface Contents System configuration Introduction to S20LPStation hardware ∙ OverviewT2N include of S20LP Port SN325 SN325∙ Status LEDs S20LP port for T2N PU245NFor SN325 ∙ Station number setting switches ∙ Transmission cable connectors∙ Reset switch only SN325 ∙ Loader portLS overview Menu⎯ 10 ⎯ Specifications S20LP system specificationsS20LP-station specifications Scan transmission overview Setting the data send block by S-LS Allocation and network assignment by T-PDSSetting for data linkage Station number settingSettings on T-PDS Link PDS screen example Block Send Receive ⎯ 18 ⎯ Global ⎯ 20 ⎯ Settings on S-LS ⎯ 22 ⎯ ⎯ 23 ⎯ ⎯ 24 ⎯ ∙ Scan Access ∙ Start with Standby mode∙ Scan Transmission ∙ Message Transmission∙ Target Scan Time Data linkage example ∙ Settings on T-PDS Setting on S-LS LS setting screen 2 for STN #2 Cable connections RAS function Behavior in trouble∙ Station down ∙ Transmission cable breakageSelf-diagnostic function At initialization at power onDuring operation LED indication SN325T2N RAS information monitored in T2N/T3H Station status Online mapStandby map Loop map Only T2NRAS information monitored on S-LS Number 1-64 on the screen shows the Station numberSelf Station Station No.01 Offline Select the Station Number Click the Status Display Possible error message are as follows Station down informationInstruction Specification Expanded data transfer instructionInstruction format FunctionParameter and construction Transfer parameter tableSample program ∙ OperationRemarks Message transmission Message transmissionComputer link protocol PC link protocol∙ Send Transfer parameters a CMDStatus B TermSTS Status Meaning Detailed Information Send completion status PC link protocol transmission Data write Transfer parametersRID Status See 7.3 5 for details on bits C, D, E, and F Important itemsXW/YW PC link protocol transmission Data read ⎯ 57 ⎯ SW067 Write enabled PC link protocol transmission program RemarksLength END Appendix Scan cycle⎯ 63 ⎯ PDS remote programming PDS Setup options screen