6 F 3 B 0 3 5 6

Remarks

When writing data into S20LP scan memory, confirm that the address range is S20LP's data send block.

If S20LP scan memory is accessed only by this XFER instruction, the network assignment, i.e. "LINK" or "GLOBAL" setting, is not necessary.

If W register is designated as source and destination, don't set the network assignment, i.e. "LINK" or "GLOBAL".

45

Image 46
Contents T2N/T3H stations Important Information Preface Contents System configuration Introduction to S20LP∙ Overview Station hardwareT2N include of S20LP Port SN325 SN325S20LP port for T2N PU245N ∙ Status LEDsFor SN325 ∙ Reset switch only SN325 ∙ Station number setting switches∙ Transmission cable connectors ∙ Loader portLS overview Menu⎯ 10 ⎯ S20LP system specifications SpecificationsS20LP-station specifications Scan transmission overview Setting the data send block by S-LS Allocation and network assignment by T-PDSStation number setting Setting for data linkageSettings on T-PDS Link PDS screen example Block Send Receive ⎯ 18 ⎯ Global ⎯ 20 ⎯ Settings on S-LS ⎯ 22 ⎯ ⎯ 23 ⎯ ⎯ 24 ⎯ ∙ Scan Transmission ∙ Scan Access∙ Start with Standby mode ∙ Message Transmission∙ Target Scan Time Data linkage example ∙ Settings on T-PDS Setting on S-LS LS setting screen 2 for STN #2 Cable connections ∙ Station down RAS functionBehavior in trouble ∙ Transmission cable breakageAt initialization at power on Self-diagnostic functionDuring operation SN325 LED indicationT2N RAS information monitored in T2N/T3H Station status Online mapStandby map Loop map Only T2NRAS information monitored on S-LS Number 1-64 on the screen shows the Station numberSelf Station Station No.01 Offline Select the Station Number Click the Status Display Possible error message are as follows Station down informationInstruction format Instruction SpecificationExpanded data transfer instruction FunctionParameter and construction Transfer parameter tableSample program ∙ OperationRemarks Computer link protocol Message transmissionMessage transmission PC link protocol∙ Send Transfer parameters a CMDStatus B TermSTS Status Meaning Detailed Information Send completion status PC link protocol transmission Data write Transfer parametersRID Status See 7.3 5 for details on bits C, D, E, and F Important itemsXW/YW PC link protocol transmission Data read ⎯ 57 ⎯ SW067 Write enabled PC link protocol transmission program RemarksLength END Appendix Scan cycle⎯ 63 ⎯ PDS remote programming PDS Setup options screen