Operating the UPS

Display Panel Layout

Function

Control

Startup on

Battery

Button

Button

 

 

ON LINE (green lamp)

 

Lights green when the UPS’s inverter is

 

supplying power to the load.

 

AC INPUT (green lamp)

 

Lights green when normal AC input power

 

is being supplied to the UPS unit.

 

WARNING/FAULT (red lamp)

 

Lights red when the UPS unit is

 

experiencing an abnormal condition.

 

BATTERY (red lamp)

 

Lights red to indicate that a condition exists

 

that is affecting the batteries.

Starting the UPS System

Once the modules have been connected as shown in the preceding section (UPS Connections, page 10) the UPS system is ready to be started. There are two ways to start the system: from AC input power (if present) or from batteries. If not already done, switch the input breaker on (figure 1, page 9). If the “AC Input” LED is lit, proceed on to “Starting when AC power is available”. If the LED is not lit, there is no AC power available. If the unit is to be started when AC power is not available proceed to “Starting on DC power.”

Starting When AC Power is Available

If the system is being started with AC input power the system is started by switching the RUN/STOP switch to the RUN position (RUN = I, STOP = 0). When the RUN/STOP switch is in the RUN position both the “AC Input” and the “On Line” LEDs should be lit. When the unit is started with AC input power it is advisable to allow time for the batteries to fully charge before any load is connected (see “Battery Recharge Time”, page 15).

11

Image 11
Contents Series Toshiba Important Notice Table of Contents General Safety Instructions Important Safety Instructions Instructions Importantes Concernant LA Sécurité Inspection of the New UPS Equipment Inspection/InstallationInstallation Precautions Operating PrecautionsElectronics Module External LayoutStandard Module Connections Battery ModuleUPS Connections Starting the UPS System Starting When AC Power is AvailableOperating the UPS Display Panel LayoutStopping the UPS Starting on DC PowerUPS Display Status and Operating Condition Parallel On Line ............. On Alarm will Fan Speed Battery Backup TimeBattery Recharge Time Load Shed FunctionFunction Control Button Battery Check FunctionToshiba Toshiba Fixed Frequency Mode Dry Contacts RS-232C Option Card Slot TroubleshootingCommunication Interface Low Battery Alarm will Battery Over Heat Input Alarm will Shutdown Backup.............. On Alarm FaultsDC Bus Over Voltage Imbalance Output Under Output Over 100% ................ On Voltage Alarm will Avoid Storage of UPS EquipmentParts Replacement Preventive and Scheduled Maintenance/Parts ReplacementPreventive Maintenance UF1A1A020C6RK UF1A1A024C6RK Appendix a SpecificationsAppendix B Fan Speed Control Appendix C System Overload Rating Appendix D Parallel Operation Appendix E Bypass Undervoltage / Overvoltage Appendix G Weights and Dimensions Limitations and Exclusions Procedure Toshiba Toshiba Toshiba International Corporation