Appendix C: System Overload Rating

The 1700 Series Rackmount UPS is capable of supporting short duration overloads. When operating in the On Line mode output overloading of 125% of the rated output current can be supported for 1 minute, and 150% for 30 seconds. If the overload continues the unit will switch to bypass mode. When in bypass mode the 1700 Series overload capacity is limited by the input breaker. The following graph shows the response of the breaker depending on the applied load. The two lines shown on the graph represent the upper and lower limits of the breaker response. The response of a particular breaker could fall anywhere between these two lines.

If the load capacity of the breaker is exceeded the breaker will trip, shutting down both the UPS and the attached loads. If the breaker’s capacity is not exceeded the unit will continue to operate in the bypass mode until the applied load is reduced. When the load on the UPS is reduced to within the specified limits the UPS will automatically return to On Line mode.

31

Image 31
Contents Series Toshiba Important Notice Table of Contents General Safety Instructions Important Safety Instructions Instructions Importantes Concernant LA Sécurité Inspection of the New UPS Equipment Inspection/InstallationInstallation Precautions Operating PrecautionsElectronics Module External LayoutUPS Connections Battery ModuleStandard Module Connections Starting the UPS System Starting When AC Power is AvailableOperating the UPS Display Panel LayoutStopping the UPS Starting on DC PowerUPS Display Status and Operating Condition Parallel On Line ............. On Alarm will Fan Speed Battery Backup TimeBattery Recharge Time Load Shed FunctionFunction Control Button Battery Check FunctionToshiba Toshiba Fixed Frequency Mode Communication Interface TroubleshootingDry Contacts RS-232C Option Card Slot Low Battery Alarm will Battery Over Heat Input Alarm will Shutdown Backup.............. On Alarm FaultsDC Bus Over Voltage Imbalance Output Under Output Over 100% ................ On Voltage Alarm will Avoid Storage of UPS EquipmentPreventive Maintenance Preventive and Scheduled Maintenance/Parts ReplacementParts Replacement UF1A1A020C6RK UF1A1A024C6RK Appendix a SpecificationsAppendix B Fan Speed Control Appendix C System Overload Rating Appendix D Parallel Operation Appendix E Bypass Undervoltage / Overvoltage Appendix G Weights and Dimensions Limitations and Exclusions Procedure Toshiba Toshiba Toshiba International Corporation
Related manuals
Manual 2 pages 63.93 Kb