Toshiba 1700 user manual Limitations and Exclusions

Page 35

TOSHIBA

TOSHIBA INTERNATIONAL CORPORATION LIMITED WARRANTY POLICY

(48 contiguous U.S. States, Canada, Mexico)

(UNINTERRUPTIBLE POWER SUPPLIES-UPS)

TOSHIBA INTERNATIONAL CORPORATION (“TIC”) warrants that the 1700 Series Uninterruptible Power Supplies (“UPS”) and Uninterruptible Power Supply Battery (“BATTERY”) (external battery cabinet) sold by TIC to the end user (“User”) shall be free of defects in material and workmanship.

Series

Capacity

UPS Unit

Battery

Toshiba Dispatch

Warranty1

 

On-Site2

Warranty1

On-Site2

1700

1.5, 2.4 kva

36 months

 

No, Depot

24 months

No, Depot

M-F, 8AM-5PM CT

Note 1:

The warranty period begins from the shipment date. The shipment date is determined by the

 

date on the TIC Bill of Lading.

 

 

 

 

Note 2:

For the 1700 Series the warranty applies if the unit is sent and returned (paid for) by the user

 

to/from the Toshiba plant or a Toshiba designated Authorized Service Center.

If any UPS, part of UPS, and/or BATTERY fails to conform or is defective then TIC will repair or replace it at TIC’s option.

LIMITATIONS AND EXCLUSIONS

This limited warranty shall not cover the UPS, UPS part, or BATTERY during their respective warranty periods, if the following storage, maintenance, installation, operating conditions are not met throughout the warranty periods (5 conditions below):

VALVE REGUALATED LEAD ACID (VRLA) BATTERIES FOR TOSHIBA UPS

REQUIRED OPERATING CONDITIONS

1.

Temperature

Annual Average

Temperature per cell < 32°C

Temperature 25°C (77°F)

(89°F) for more than 30 days

 

 

 

 

 

Maximum Number of Cycles

 

 

Discharge time

(24 months)

2.

Maximum number of full

30 minutes

69

 

charge/discharge cycles

15 minutes

86

 

 

10 minutes

110

 

 

5 minutes

130

 

VALVE REGUALATED

LEAD ACID (VRLA) BATTERIES FOT TOSHIBA UPS

 

INSTALLATION AND MAINTENANCE CONDITIONS

3.

Storage

While UPS is in transit or storage it must always be in

 

 

suitable temperature (see condition 1).

4.

External Batteries

Parallel battery string applications must be approved by TIC

 

 

in writing.

 

5.

Idle Batteries

User must recharge the batteries if not in use (charged) for

 

 

more than 6 months.

 

1.This Warranty does not cover damage or defect caused by misuse, improper application, wrong or inadequate electrical current/voltage/frequency, inadequate connections, inadequate water or drain services, user negligence, repair by non- Toshiba designated personnel, accident during shipment, tampering, alterations, a change in UPS and/or BATTERY location or application, exposure to the elements, acts of God, theft, sabotage, installation contrary to TIC's recommendations or specifications (Published Operation Manuals), also if serial numbers have been altered, defaced, or removed.

2.Repair or replacement of a defective UPS, UPS part, and/or BATTERY does not extend the respective original warranty period. All defective UPS, UPS parts, and/or BATTERIES shall be the property of TIC upon replacement.

3.This warranty shall constitute the sole and exclusive remedy of all purchasers and users of the UPS, UPS part, and/or BATTERY. TIC’s responsibility for UPS, UPS Parts, and/or BATTERY shall not exceed one times the net UPS and/or BATTERY purchase price. TIC HEREBY EXPRESSLY DISCLAIMS ALL OTHER EXPRESS,

STATUTORY AND IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

35

Image 35
Contents Series Toshiba Important Notice Table of Contents General Safety Instructions Important Safety Instructions Instructions Importantes Concernant LA Sécurité Inspection of the New UPS Equipment Inspection/InstallationInstallation Precautions Operating PrecautionsElectronics Module External LayoutStandard Module Connections Battery ModuleUPS Connections Starting the UPS System Starting When AC Power is AvailableOperating the UPS Display Panel LayoutStopping the UPS Starting on DC PowerUPS Display Status and Operating Condition Parallel On Line ............. On Alarm will Fan Speed Battery Backup TimeBattery Recharge Time Load Shed FunctionFunction Control Button Battery Check FunctionToshiba Toshiba Fixed Frequency Mode Dry Contacts RS-232C Option Card Slot TroubleshootingCommunication Interface Low Battery Alarm will Battery Over Heat Input Alarm will Shutdown Backup.............. On Alarm FaultsDC Bus Over Voltage Imbalance Output Under Output Over 100% ................ On Voltage Alarm will Avoid Storage of UPS EquipmentParts Replacement Preventive and Scheduled Maintenance/Parts ReplacementPreventive Maintenance UF1A1A020C6RK UF1A1A024C6RK Appendix a SpecificationsAppendix B Fan Speed Control Appendix C System Overload Rating Appendix D Parallel Operation Appendix E Bypass Undervoltage / Overvoltage Appendix G Weights and Dimensions Limitations and Exclusions Procedure Toshiba Toshiba Toshiba International Corporation