Siemens M1 manual ATBn Select GSM module’s operating mode, Atb, ATB99

Page 22

Technical reference section

Example:

Your PC is set to 19200 baud, i.e. higher than the maximum GSM transfer rate of 9600 bit/s. This means that the GSM module receives more data from the PC than it can transfer to the GSM network. In order to prevent a data overflow, the module must be able to interrupt the data flow from the PC. This is accomplished by means of the RTS/ CTS hardware data flow control.

ATBn - Select GSM module’s operating mode

The ATBn command also allows you to set the GSM module’s operating mode perma- nently for all connections.

ATBn

 

 

 

 

 

[n=7,11,13,25,27,29,70,99]

 

 

 

 

 

 

 

 

 

 

 

 

 

Result

Option

Bit/s

 

Synchronism

 

Distant station

 

 

 

 

 

 

 

 

 

 

 

 

ATB99

 

 

 

 

 

Automatically sets the mode to match

 

 

 

 

 

 

the baud rate set for the PC.

 

 

 

 

 

 

Factory configuration

 

 

 

 

 

 

ATB 7

2400

 

Asynchronous

 

V.22bis

 

 

 

 

 

 

ATB11

4800

 

Asynchronous

 

V.32

 

 

 

 

 

 

ATB13

9600

 

Asynchronous

 

V.32

 

 

 

 

 

 

ATB25

2400

 

Asynchronous

 

V.110 ISDN

 

 

 

 

 

 

ATB27

4800

 

Asynchronous

 

V.110 ISDN

 

 

 

 

 

 

ATB29

9600

 

Asynchronous

 

V.110 ISDN

 

 

 

 

 

 

ATB70

9600

 

Asynchronous

 

Fax Group 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example:

 

 

 

 

 

 

Enter:

 

 

 

ATB13

 

 

GSM module:

 

Permanently switches the mode to 9600 bit/s with the result that

 

 

 

 

all radio connections are permanently set to a transfer rate of

 

 

 

 

9600 bit/s.

 

 

Enter:

 

 

 

ATB99

 

 

GSM module

 

Automatically changes to the rate of the COM interface.

21

Image 22
Contents GSM Contents Technical reference section Contents GSM documentation Technical dataGeneral information Features GSM Module M1 Product descriptionSIM card Hybrid connector manufacturer-specificGSM Module M1 Description of the interfaces InterfaceSwitching the GSM module on/off Installation / startup Mounting the modulePower supply / power consumption Cable assignmentPower consumption Installation / startupSetting / testing the COM interface Overvoltage / undervoltageATB13 Setting the GSM radio transfer rateATB7 +CPIN SIM PIN Setting up and clearing down connectionsAT+CPIN? AT+CPIN=1234AT&F TroubleshootingATH Own errors Connection cannot be set upSystem errors GSM module does not dial Incorrect characters on screenCannot receive fax Overview of AT commands General AT commands GSM AT commands GSM Overview of AT commandsSMS AT commands GSM Command syntax of the AT standard AT command line prefixConnecting to your GSM module Technical reference section AT standardATD0123456789 Technical reference sectionATH ATS7?Q0E1 AT&F0 Ring Error Connect No CarrierEscape command Command modeTransparent mode Operating modesSetting the transfer rate ATOn Return to transparent modeATH Go on-hook ATB ATBn Select GSM module’s operating modeATB99 Valid dial strings ATD Dial a telephone numberATD Dial ATD+4989telephone numberAtdl AT%Dn Automatic dialing with DTRATD123456789 AT&Z0=123456789ATS0=n Auto-answer mode Displaying and storing a configurationATA Answer a call Telephone Numbers &Z0= AT&V Active ProfileStored Profile Z1= Z2= Z3=Screen outputs Limits of screen outputs ATEn Command echoATQn Activate and deactivate result codes ATXn Extended connect message Control line options AT&Cn Data Carrier Detect DCD optionsAT&Dn Data Terminal Ready DTR options Memory commandsData flow control AT&Z0 = AT&Wn Store configurationAT&Zn=x Store telephone number ATDS=n Dial stored telephone numberATZn Load user profile AT+C commands for GSMAT&Yn Configuration at power-up AT+CXXSN = ?AT+CGMM AT+CGMI+CGMI Siemens +CGMM M1AT+CGSN Request product serial number ID AT+CEER Extended error reportAT+CHUP Hangup call AT+CEER AT+CMEE Report mobile equipment errorEnter GSM module+CME Error AT+CREG?AT+CREG Network registration AT+CREG?AT+COPS? EnterAT+CREG? GSM module +CREG 0,0 = not registeredAT+COPS Operator selection AT+COPS=?AT+COPS=? Display list of available network operators AT+COPS?+COPS 0, 0, Operator Name AT+COPS=?Telekom PrivatAT+CPIN Enter PIN and query blocks +CME Error Wrong Password AT+CPIN2 Enter PIN2 and query PIN2 blocksAT+CPWD=? AT+CPWD Change passwordAT+CPIN2=1234 +CPWD SC,8,PS,8, P2,8AT+CSQ AT+CSQ Signal qualityErrors ReceiveAT+CKPD=? AT+CKPD Keypad controlAT+CKPD=? +CKPD 0123456789*#CDEISUXYZAT+CXXSN Single-numbering parameterization AT+CXXSN=?+CXXSN 0,1,2 AT+CXXSN=?AT+CXXSN=2 +CXXMOC 0,1 AT+CXXMOC=?AT+CXXMOC=1 AT+CPBS=? AT+CPBS Select phonebook memory storage+CPBS MD , SM , OW , FD AT+CPBR=? AT+CPBR Read phonebook entriesAT+CPBR=? +CPBR index, number length, textAT+CPBW Write phonebook entry AT+CBST? AT+CBST Select bearer service typeAT+CBST=? AT+CRC=? AT+CRC Cellular result codeAT+CRC? AT+CRC?AT+CLIP=? AT+CLIP Calling line identification presentationAT+CLIP? AT+CLIP?AT+CPAS=? AT+CPAS Phone activity statusAT+CPAS=? +CPAS 0 1 2 3 4AT+FCLASS=? AT+FCLASS Select modeAT+FCLASS? AT+FCLASS=?AT+CXXCID Card identification AT+C commands for the short message service SMSAT+CXXCID=? Values implemented AT+CSMS Select message serviceParameter command syntax AT+CPMS Preferred message storageAT+CSCA Service center address AT+CMGF Message formatIf PDU mode +CMGF=0 If send is successful Action command syntaxIf PDU mode +CMGF=0 and command successful AT+CMGR Read messageAT+CMGD Delete message AT+CMGW Write message to memoryAT+CNMI New message indications +CMGL=? AT+CMS Error message service failure result codesAT+CMGL List messages Value definitionsAT+FDT= S-registersAT+FCR= AT+FAAAT+FBUF?AT+FBOR ATSn=x Write to an S-register ATSn? Read an S-registerEnterATS0?S7? ATS0=3Binary and decimal values in S-registers You wish to enter the following parameter values Bit position registersDecimal input and binary storage Overview of the S-registers Please note OFFDTR on OFF Technical reference section ABC AT&T1AT&T0 ATIn Display GSM module I-data Technical data General InterfaceTechnical data Hybrid connector manufacturer-specific FAX G3 Technical data GSM modesFax DataEtsi contact GSM documentation GSM reference documentsEuropean Telecommunications Standards Institute Service General information CE-SignGeneral information