Siemens M1 AT+CPBR Read phonebook entries, At+Cpbr=?, +CPBR index, number length, text, Length

Page 49

Technical reference section

AT+CPBR - Read phonebook entries

This command allows you to read the phonebook that was selected by means of the AT+CPBS command. You must also enter the number of the relevant position or a range of numbers.

 

AT+CPBR

 

 

Command

Result

 

 

AT+CPBR=index1[,index2]

Reads the phonebook entry with the number index1.

 

If you also enter a second index, reads the phone-

 

book from index1 to index2.

 

 

AT+CPBR=?

Provides you with information on the maximum

 

number of entries that can be contained in the direc-

 

tory and the maximum size of these entries.

 

 

The test command provides you with information on the format of the phonebook that was selected by means of AT+CPBS.

 

AT+CPBR=?

 

 

Command

AT+CPBR=?

 

 

Result code

+CPBR: <index>, <number length>, <text

 

length>

 

 

 

Meaning

 

 

Index

Maximum number of entries in the phonebook

 

 

Number length

Length of a telephone number

 

 

Text length

Length of a telephone number name

 

 

48

Image 49
Contents GSM Contents Technical reference section Contents GSM documentation Technical dataGeneral information GSM Module M1 Product description FeaturesGSM Module M1 Description of the interfaces Hybrid connector manufacturer-specificSIM card InterfacePower supply / power consumption Installation / startup Mounting the moduleSwitching the GSM module on/off Cable assignmentSetting / testing the COM interface Installation / startupPower consumption Overvoltage / undervoltageATB13 Setting the GSM radio transfer rateATB7 AT+CPIN? Setting up and clearing down connections+CPIN SIM PIN AT+CPIN=1234AT&F TroubleshootingATH Own errors Connection cannot be set upSystem errors GSM module does not dial Incorrect characters on screenCannot receive fax Overview of AT commands General AT commands GSM AT commands GSM Overview of AT commandsSMS AT commands GSM Connecting to your GSM module AT command line prefixCommand syntax of the AT standard Technical reference section AT standardATH ATS7?Q0E1 Technical reference sectionATD0123456789 AT&F0Connect ErrorRing No CarrierTransparent mode Command modeEscape command Operating modesSetting the transfer rate ATOn Return to transparent modeATH Go on-hook ATB ATBn Select GSM module’s operating modeATB99 ATD ATD Dial a telephone numberValid dial strings Dial ATD+4989telephone numberATD123456789 AT%Dn Automatic dialing with DTRAtdl AT&Z0=123456789ATS0=n Auto-answer mode Displaying and storing a configurationATA Answer a call Stored Profile AT&V Active ProfileTelephone Numbers &Z0= Z1= Z2= Z3=Screen outputs Limits of screen outputs ATEn Command echoATQn Activate and deactivate result codes Control line options AT&Cn Data Carrier Detect DCD options ATXn Extended connect messageAT&Dn Data Terminal Ready DTR options Memory commandsData flow control AT&Zn=x Store telephone number AT&Wn Store configurationAT&Z0 = ATDS=n Dial stored telephone numberAT&Yn Configuration at power-up AT+C commands for GSMATZn Load user profile AT+CXXSN = ?+CGMI Siemens AT+CGMIAT+CGMM +CGMM M1AT+CGSN Request product serial number ID AT+CEER Extended error reportAT+CHUP Hangup call Enter AT+CMEE Report mobile equipment errorAT+CEER GSM moduleAT+CREG? +CME ErrorAT+CREG? AT+CREG Network registrationAT+COPS Operator selection EnterAT+CREG? GSM module +CREG 0,0 = not registeredAT+COPS? AT+COPS=?+COPS 0, 0, Operator Name AT+COPS?AT+COPS=? Display list of available network operators AT+COPS=?Privat TelekomAT+CPIN Enter PIN and query blocks AT+CPIN2 Enter PIN2 and query PIN2 blocks +CME Error Wrong PasswordAT+CPIN2=1234 AT+CPWD Change passwordAT+CPWD=? +CPWD SC,8,PS,8, P2,8Errors AT+CSQ Signal qualityAT+CSQ ReceiveAT+CKPD=? AT+CKPD Keypad controlAT+CKPD=? +CKPD 0123456789*#CDEISUXYZAT+CXXSN=? AT+CXXSN Single-numbering parameterization +CXXSN 0,1,2 AT+CXXSN=? AT+CXXSN=2 +CXXMOC 0,1 AT+CXXMOC=?AT+CXXMOC=1 AT+CPBS=? AT+CPBS Select phonebook memory storage+CPBS MD , SM , OW , FD AT+CPBR=? AT+CPBR Read phonebook entriesAT+CPBR=? +CPBR index, number length, textAT+CPBW Write phonebook entry AT+CBST? AT+CBST Select bearer service typeAT+CBST=? AT+CRC? AT+CRC Cellular result codeAT+CRC=? AT+CRC?AT+CLIP? AT+CLIP Calling line identification presentationAT+CLIP=? AT+CLIP?AT+CPAS=? AT+CPAS Phone activity statusAT+CPAS=? +CPAS 0 1 2 3 4AT+FCLASS? AT+FCLASS Select modeAT+FCLASS=? AT+FCLASS=?AT+CXXCID Card identification AT+C commands for the short message service SMSAT+CXXCID=? Parameter command syntax AT+CSMS Select message serviceValues implemented AT+CPMS Preferred message storageAT+CMGF Message format AT+CSCA Service center addressIf PDU mode +CMGF=0 and command successful Action command syntaxIf PDU mode +CMGF=0 If send is successful AT+CMGR Read messageAT+CMGD Delete message AT+CMGW Write message to memoryAT+CNMI New message indications AT+CMGL List messages AT+CMS Error message service failure result codes+CMGL=? Value definitionsAT+FDT= S-registersAT+FCR= AT+FAAAT+FBUF?AT+FBOR EnterATS0?S7? ATSn? Read an S-registerATSn=x Write to an S-register ATS0=3Binary and decimal values in S-registers You wish to enter the following parameter values Bit position registersDecimal input and binary storage OFF Overview of the S-registers Please noteDTR on OFF Technical reference section ABC AT&T1AT&T0 ATIn Display GSM module I-data Interface Technical data GeneralTechnical data Hybrid connector manufacturer-specific Fax Technical data GSM modesFAX G3 DataEtsi contact GSM documentation GSM reference documentsEuropean Telecommunications Standards Institute General information CE-Sign ServiceGeneral information