Technical data | 13 | ||
13.1 | General specifications |
| |
|
|
|
|
|
| General technical data |
|
|
| Order numbers | |
|
|
| documentation) |
|
| Dimensions | 430.4x177.4x444.4 (WxHxD in mm). Detailed |
|
|
| dimensional specifications are found in the "Dimensional |
|
|
| drawings" section. |
|
| Weight | Approx. 19 kg |
|
| Supply voltage (UN) | 100 V AC to 240 V AC (90 to 264 V AC) |
|
| Line voltage frequency | 50 – 60 Hz |
|
| Transient voltage interruption | 16 ms at 0.85 UN |
|
|
| (max. 10 events per; min. recovery time 1s) |
|
| Power consumption (at 210 W secondary | 310 W (efficiency approx. 68%) |
|
| power) |
|
|
| Max. current output (AC) | +3.3 V/24 A |
|
|
| +5V/26A |
|
|
| max. 190 W total allowed |
|
|
| |
|
|
| +12V/15A |
|
|
| |
|
|
| +5Vaux/2A |
|
| Noise emission | < 45 dB(A) to DIN 45635 |
|
| Degree of protection | IP 30 with closed front door, IP 20 at the back in |
|
|
| conformity to EN 60529 |
|
| Safety |
|
|
| Protection class | Protection class I to IEC 61140 |
|
| Safety specifications | |
|
| Electromagnetic compatibility (EMC) |
|
|
| Emitted interference (AC) | EN 55022 Class A, FCC class A |
|
|
| EN |
|
| Noise immunity: | ± 2 kV, (according to IEC |
|
| Mains borne disturbance variables on | ± 1 kV; (according to IEC |
|
| supply lines | ± 2 kV; (according to IEC |
|
| Noise immunity on signal lines | ± 1 kV;(according to IEC |
|
|
| < 10 m) |
|
|
| ± 2 kV, (according to IEC |
|
|
| length > 30 m) |
SIMATIC Rack PC IL 43 | |||