4 Electromagnetic Compatibility | 4 |
|
The Panel PC 670/870 meets the requirements of German EMC laws as well as European Directives concerning EMC.
The following includes information on interference immunity of the Panel PC 670/870 and on interference suppression.
The Panel PC 670/870s have been conceived as installation devices with Protection Class IP65 on the front side. Their installation in grounded metal cabinets (e.g. 8 MC cabinet according to the NV21 catalog) guarantees compliance with EN
The touch panel versions without a USB interface on the front side meet the requirements complying with NEMA 4.
Pulse shaped interference
Pulse shaped interference | Tested with | Corresponds to | |
|
| Severity Level | |
Electrostatic discharge | 8 kV | 3 | (Air Discharge) |
complying with | 4 kV | 2 | (Contact |
EN |
| Discharge) | |
Burst Impulses (rapid, | 2 kV (Power Line) | 3 |
|
temporary interference) | 2 kV (Process Data Line) | 3 |
|
according to EN |
|
|
|
|
|
|
|
|
|
| |
(Surge) according to |
|
|
|
EN |
|
|
|
(24 V model only with |
|
|
|
protective lightning conductor |
|
|
|
KT Type A D 24 V, Order No. |
|
|
|
DSN:919253) |
|
|
|
Asymmetric Connection | 2 kV (Power Line) | 3 |
|
Symmetric Connection | 1 kV (Power Line) | 3 |
|
|
|
|
|
SIMATIC Panel PC 670/870 |