Siemens manual Setting the IP address of the ChemWeb Server, Network connection in a LAN

Page 14

Setting the IP address of the ChemWeb Server

Initialization of the ChemWeb Server after switching on the power supply or after a reset may take up to several minutes depending on the configuration! During this time the ChemWeb Server does not respond!

The ChemWeb Server must be installed completely before the initial startup!

Before starting the setup of a connection, it must be decided which type of connection is to be used for the connection to the ChemWeb Server. There are four different types of connection to the ChemWeb Server:

-Network connection in a LAN

-Direct network connection

-Switched connection via modem

-Null modem connection via serial interface

Network connection in a LAN

The connection to the ChemWeb Server can be set up from any laptop computer/PC in the network. It is assumed that the laptop computer/PC to be used is already installed as user of the network. As a fixed IP address and a network mask are always preset at the ChemWeb Server before leaving the factory, these must be adapted to the network. For this purpose, the supplied CD or floppy disk is required. The IP address and network mask preset at the ChemWeb Server in the factory are:

IP address:

192.168.200.4

Network mask:

255.255.255.0

The ChemWeb Server is connected to a network switch or hub using a standard patch cable. If an uplink port is available at the network switch or hub, the supplied crossed patch cable can also be used.

The required parameters (IP address, network mask, DHCP) must be provided by the network administrator. To change the IP address, the network mask or the DCHP operating mode of the ChemWeb Server,

Direct network connection

The connection is always set up between a laptop computer/PC with network board (10MB/s) and the ChemWeb Server via the supplied null modem cable. The supplied CD or floppy disk is only required if the fixed IP address and/or network mask preset at the ChemWeb Server in the factory cannot be used. A fixed IP address and network mask must be assigned to the laptop computer/PC. The ChemWeb Server and the laptop computer must always have the same network mask and an IP address in the same address range. The IP address must, however, not be identical for both.

Example:

ChemWeb-Server

Laptop computer/PC

 

IP-address:

192.168.200.4

192.168.200.1

Network mask:

255.255.255.0

255.255.255.0

If the IP address or/and the network mask of the ChemWeb Server are to be changed,

With WindowsXP, a network connection is set up automatically as soon as a network board is identified in the laptop computer/PC. Just a fixed IP address and a network mask have to be assigned manually.

8

Image 14
Contents ChemWeb Server Page Table of Contents Software and Firmware License Disconnect and Lockout Power Before Servicing Page Overview of ChemWeb Server Power Supply Description of ChemWeb ServerCOM 0 W&T RS485 bus W&T RS232 Ext. ResetInputs IN1, IN2 Telephone line only for analog or Isdn version COM 1 RS232 null modemEthernet / 10BaseT RJ45 OutputsCompactFlash slot CF LED displaysRS485 bus system Connecting more than one ChemWeb ServerInstallation of RS485 bus 390 Ohm +/- 2 % Direct network connection Setting the IP address of the ChemWeb ServerNetwork connection in a LAN Setting the IP address of the ChemWeb Server Switched connection via modem Analog modem Isdn modemSetting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Null modem connection via serial interface Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server without Dhcp Setting the IP address of the ChemWeb Server with Dhcp Connection via InternetBasic settings via a Browser StartupBus scan Server SetupISP configuration Mail configuration Event configuration Time/date setting Server commandsChange passwords Name configuration Chip info Operation via Web Browser Operation and Data AccessDisplay and configuration window Navigation windowOperation and Data Access 03 04 a 00.TXT Log filesData access via FTP Backing up log filesData access to CompactFlash card with card scanner Data access via Web BrowserTechnical data Appendix Tested Web Browser Appendix Appendix Page Siemens All Rights Reserved