Overview of ChemWeb Server

The ChemWeb Server is used for central recording, monitoring and logging of the process data in potable and swimming pool water treatment plants. It is especially suitable for smaller installations without process display but which are to be installed with a data recording system with simple display. Another application example would be in unmanned plants such as potable water stations, in which recording of the measured data is to be accomplished by remote access.

The data exchange with the MG/L 5 and metering technology is accomplished via a serial digital interface. Data of process devices without serial digital interface can be recorded by the ChemWeb Server by means of the process data interface (PDI). By using an RS485 bus system, a variety of process parameters from the individual devices can be recorded, with little wiring. It is also possible to change certain process parameters with the digital communication. Parameters such as set point values, alarm contacts, etc. can be modified centrally via the ChemWeb Server. The RS485 bus system can be used for distances of up to 4,000 ft (1200 m).

To fetch the measured data from the connected devices, an HTTP server is integrated in the ChemWeb Server, the page frames of which can be called up via different interfaces depending on the version:

-local network (Intranet)

-analog, ISDN modem

-data exchange via CompactFlash card

-serial interface RS232

The ChemWeb Server behaves as a master at the RS485 bus and therefore cannot be used in connection with other data recording systems such as e.g. control stations, CMS, OPC servers, SECO S7, MF485 printer logging, or Profibus DP converters.

1

Image 7
Contents ChemWeb Server Page Table of Contents Software and Firmware License Disconnect and Lockout Power Before Servicing Page Overview of ChemWeb Server Description of ChemWeb Server Power SupplyInputs IN1, IN2 Ext. ResetCOM 0 W&T RS485 bus W&T RS232 Outputs COM 1 RS232 null modemEthernet / 10BaseT RJ45 Telephone line only for analog or Isdn versionLED displays CompactFlash slot CFInstallation of RS485 bus Connecting more than one ChemWeb ServerRS485 bus system 390 Ohm +/- 2 % Network connection in a LAN Setting the IP address of the ChemWeb ServerDirect network connection Setting the IP address of the ChemWeb Server Analog modem Isdn modem Switched connection via modemSetting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Null modem connection via serial interface Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server without Dhcp Connection via Internet Setting the IP address of the ChemWeb Server with DhcpStartup Basic settings via a BrowserISP configuration Server SetupBus scan Mail configuration Event configuration Server commands Time/date settingChange passwords Name configuration Chip info Navigation window Operation and Data AccessDisplay and configuration window Operation via Web BrowserOperation and Data Access Log files 03 04 a 00.TXTBacking up log files Data access via FTPData access via Web Browser Data access to CompactFlash card with card scannerTechnical data Appendix Tested Web Browser Appendix Appendix Page Siemens All Rights Reserved