Siemens manual Setting the IP address of the ChemWeb Server without Dhcp

Page 27

Setting the IP address of the ChemWeb Server

Start menu item “Find” in the “CHIP” menu. The program then locates all ChemWeb Servers connected to this network segment independent of the set IP address and network mask, and lists all set data. Note the number in the first column “Snr” of the ChemWeb at which a setting is to be made. This number corresponds to the last 5 digits of the MAC address of the ChemWeb Server (see label at ChemWeb Server).

Now change to menu item “IP config” in the “CHIP” menu. Type the traced number in the first box “Serial number of CHIP”. Before filling in the other entry boxes, a difference must be made between operation with or without DHCP server.

Setting the IP address of the ChemWeb Server without DHCP

Your network administrator must assign you a fixed IP address and inform you about the corresponding network mask. Type these data in the entry boxes “IP address” and “Network mask”. Confirm the settings by clicking “Yes”. The ChemWeb Server must then be restarted to work with the new settings.

21

Image 27
Contents ChemWeb Server Page Table of Contents Software and Firmware License Disconnect and Lockout Power Before Servicing Page Overview of ChemWeb Server Description of ChemWeb Server Power SupplyExt. Reset Inputs IN1, IN2COM 0 W&T RS485 bus W&T RS232 Outputs COM 1 RS232 null modemEthernet / 10BaseT RJ45 Telephone line only for analog or Isdn versionLED displays CompactFlash slot CFConnecting more than one ChemWeb Server Installation of RS485 busRS485 bus system 390 Ohm +/- 2 % Setting the IP address of the ChemWeb Server Network connection in a LANDirect network connection Setting the IP address of the ChemWeb Server Analog modem Isdn modem Switched connection via modemSetting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Null modem connection via serial interface Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server Setting the IP address of the ChemWeb Server without Dhcp Connection via Internet Setting the IP address of the ChemWeb Server with DhcpStartup Basic settings via a BrowserServer Setup ISP configurationBus scan Mail configuration Event configuration Server commands Time/date settingChange passwords Name configuration Chip info Navigation window Operation and Data AccessDisplay and configuration window Operation via Web BrowserOperation and Data Access Log files 03 04 a 00.TXTBacking up log files Data access via FTPData access via Web Browser Data access to CompactFlash card with card scannerTechnical data Appendix Tested Web Browser Appendix Appendix Page Siemens All Rights Reserved