Toshiba BSA4TMGS12QMR, BSA4TMTS12QMR manual Apply Floil G-488 to the cutter unit using a soft cloth

Page 37

4. PERIODIC MAINTENANCE PROCEDURE

EO18-33016A

4. PERIODIC MAINTENANCE PROCEDURE

6. Apply FLOIL G-488 to the cutter unit using a soft cloth.

CAUTION!

1.Lubrication: During parts replacement

2.Kind of oil: FLOIL G-488: 1kg can (Part No.: 19454906001)

3.Do not spray the inside of the printer with lubricants. Unsuitable oil can damage the mechanism.

All machines are generally delivered in their best condition. Efforts should be made to keep them that way. Lack of oil, or the presence of debris or dust, may cause an unexpected failure. To maintain in optimal operating condition, periodically clean the machine and apply the proper kind of oil to each part in which lubrication is needed.

Although the frequency of lubrication varies according to how often the machine is used, as a minimum it is necessary to lubricate before any part becomes dry. It is also necessary to wipe off excessive oil or it will collect dirt.

7. Confirm that the problem occurs as reported, and then take corrective action.

8. Replace the following parts, if necessary. The following table shows approximate product life for each part.

No.

Part name

Part No.

Standard interval of replacement

1

Platen

7FM00982000

50km

2

Cutter unit (B-SA204-QM-R)

-------

500,000 cuts

3

Strip module (B-SA904-H-QM)

-------

200km

NOTES: 1. The above cutter life is obtained on condition that the cutter is periodically maintained and used with TOSHBIA TEC-approved supplies by the proper method described in the manuals.

2. The above values differ depending on the thickness and substances of the media to be used. When using the cutter to cut a label stock, be sure to cut the gap between labels. Failure to do this may cause the glue to stick to the cutter and shorten the cutter life.

9. Confirm each part adjustment. Make any necessary adjustments.

10. Conduct the following tests and make sure that there is no problem.

Print test with TOSHIBA TEC-approved media and ribbon. (Print tone, print head position, etc.)

4- 4

Image 37
Contents SA4T Series Table of Contents Unpacking ProcedurePrinter Installation PS Unit Main Unit ReplacementDraw out the PS PC Board Unit from the printer SA4TM SA4TP Main PC Board Ass’yCable Protection Cover CN9 CN6 Be careful not to pinch the lead wires by the Side Panel Platen Stepping Motor and Top Cover Open Sensor Left Do not remove, just loosen Adjustment of Timing Belt Ribbon Motor/Ribbon Sensor Remove the screw to detach the Ribbon Motor Unit Remove the screws to detach the Ribbon Motors FLT-3x8 Screw Locating Pin Fan Motor Operation Panel For the B-SA4TM Remove the two screws to detach the LCD PC board Operation Panel For the B-SA4TP Panel PC Board LCD PC Board Never loosen or remove these screws Print HeadDisconnect the Print Head Cable from the Print Head Disconnect the Print Head Cable from the Print Head Media Sensor Ring Remove the Lower Sensor Cover Top by releasing the two hooks Sensor Harnesses Media Sensor Top Cover Open Sensor Right Remove the two screws from the Stepping Motor Unit Disconnect the Top Cover Open Sensor Harness Blue Periodic Maintenance Procedure Cutter Unit Set Screw Same way, clean the outside of the cutter blade Apply Floil G-488 to the cutter unit using a soft cloth Printer does not turn on TroubleshootingHead Open is displayed Eeprom Error is displayedSome printers show on Line and others show in Line Printer cannot enter the download mode Printer cannot enter the system modeHead Temp is displayed when printing is attempted Head temperature may be higher Troubleshooting Characters cannot be printed Ribbon Error is displayedRibbon is not taken up „ Situation Communication