[X-coordinate]:

Set a fine adjustment value to offset the print position perpendicular to the paper feed direction in units of 0.1 mm.

When the value is negative (-), the upper right reference coordinate shifts to the left from the zero point.

Default

0.0 mm

Range

-99.5 to +99.5 mm

[Tone Adjustment] Group [Thermal Transfer]:

Set a fine adjustment value for print density in thermal transfer print mode.

The fine adjustment value set by the Print Density Fine Adjust command [AY] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0

Range

-20 to +10

[Direct Thermal]:

Set a fine adjustment value for print density in direct thermal print mode.

The fine adjustment value set by the Print Density Fine Adjust command [AY] is displayed in the left box. When the parameter is not retrieved, the value in the left box becomes zero (0).

Default

0

Range

-20 to +10

[Command] Group

[Control Code]:

Select a control code used for command analysis.

Default

AUTO

Options

AUTO, [ESC] [LF] [NUL], { }, Manual

[Code 1]:

When "Manual" is selected for the [Control Code], set a code for the first byte in hex. format. Enter two alphanumeric characters from "0" to "F".

Entries are not case-sensitive.

Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")

Default

1B

Range

20 to FF

[Code 2]:

When "Manual" is selected for the [Control Code], set a code for the second byte in hex. format. Enter two alphanumeric characters from "0" to "F".

Entries are not case-sensitive.

Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")

Default

0A

Range

20 to FF

[Code 3]:

When "Manual" is selected for the [Control Code], set a code for the third byte in hex. format. Enter two alphanumeric characters from "0" to "F".

Entries are not case-sensitive.

Two characters indicate one HEX character. (Example: "0" -> "30" or "A" -> "41")

Default

00

Range

20 to FF

[BASIC] Group

[Basic Interpreter]:

Select whether or not the basic interpreter is enabled.

Default

Disable

Options

Disable, Enable

[Basic Trace]:

Select whether or not the basic trace is enabled.

Default

Disable

Options

Disable, Enable

40

Image 43
Contents EX Series Table of Contents Appendix Software License Agreement FeaturesIntroduction Supported PrintersNotation Outline of the FunctionsTrademark and Copyright Screens Used in This DocumentHardware Operational ConditionsDisclaimer Software Operation SystemInstallation Installation Procedure Page Uninstallation Start-up Printer Preparation Main Screen Page File MenusPage Edit View Help Printer Setting JP, QM, CN EX6T2-TUSB LAN Multi LAN Page COM Page Environment Page Password Change Progress Bar Screen Processing ScreenCompletion Screen Progress Status Page Printer List Screen Functions Parameter Setting Page Page General Tab Type Type Mode General 2 Tab Auto Shell Page Device Tab ACK/BUSY QQ READY/BUSYXON+READY AUTO, XON/XOFF AUTO, READY/BUSY RTS, XON+XOFF READY/BUSYLAN Tab HEX SnmpHEX, Ascii Wins Wlan Tab ANY Ssid on / Priority AP on / Other AP OFF EAP-FAST WEP40EAP-MD5 EAP-TLS EAP-TTLS Leap PeapHEX Wlan 2 Tab MSCHAPV2, GTC MSCHAPV2Page None Rfid TabAuto Self Diagnosis Tab MaintenanceCENTRO, LAN/WLAN, RFID, RTC JA, QM, CN Page Memory Management Tab Page Page Firmware Download DownloadPage Basic Download Page Page Create HTML/XML ROM Page Tool Tab ToolCreate External Character Tab Page X 0.5, 1.0 x 1.0, 2.0 x 2.0, 3.0 x 3.0, 1.0 x 2.0, 2.0 x Page Test Print Tab Page Slant Lines 1 dot Characters Slant Lines 3 dot Barcodes Appendix Error Message List Page Page Setup group Setup item Options or range Default Setup Items ListECO XML Auto XON+READY Auto XON+XOFF Auto READY/BUSY READY/BUSY RTS LPR ESS ID WEP MSCHAPV2 GTC None