Break Control

Controls the response of the modem to a break received from the DTE or the remote modem or the \B command. The response is different in three separate states. The first state is where the modem receives a break from the DTE when the modem is operating in data transfer mode:

Command

Effect

 

 

\K0

Enter on-line command mode, no break sent to the

remote modem.

 

 

 

\K1

Clear data buffers and send break to remote modem.

 

 

\K2

Same as 0.

 

 

\K3

Send break to remote modem immediately.

 

 

\K4

Same as 0.

 

 

\K5

Send break to remote modem in sequence with

transmitted data. (Default.)

 

 

 

The second case is where the modem is in the on-line command state (waiting for AT commands) during a data connection, and the \B is received in order to send a break to the remote modem:

Command

Effect

 

 

\K0

Clear data buffers and send break to remote modem.

 

 

\K1

Clear data buffers and send break to remote modem.

(Same as 0.)

 

 

 

\K2

Send break to remote modem immediately.

 

 

\K3

Send break to remote modem immediately. (Same as

2.)

 

 

 

\K4

Send break to remote modem in sequence with data.

 

 

\K5

Send break to remote modem in sequence with data.

(Same as 4.) (Default)

 

 

 

53

Image 53
Contents ISA Plug n Play Voice/Fax Modem Table of Contents Contacting Actiontec Customer Support IntroductionBefore You Begin For Windows 95/98 InstallationFor Windows NT 4.0 Installation Hardware Installation Installing The ModemInstalling The Modem Connecting Devices Connecting Devices to the ModemConfiguring Windows Page Finish Configuring Windows 95 OSR2Page Page Configuring Windows Page Page Page Page Configuring Windows NT Page Page Page Page Fax TIA/EIA-578 for Class 1 Fax Voice Installing Communications SoftwareInit String AT&F&C1&D2W2Windows 95/98 TroubleshootingMore Info Panel No Dialtone Error Common ProblemsCommunications Software Does Not Work COM Ports and Interrupts Appendix a Non Plug-N-Play InstallationsJumper Settings Jumpers Set To Plug-N-Play default setting Remove Installing In DOS and WindowsHardware and Driver Installation Page Repeat Last Command Appendix B AT Command SetAnswer Command ATXnCarrier Control Result CodesLast number dialed DnDialHook Control Echo CommandOnline Data Character Echo Command Request ID Information Monitor Speaker VolumeThis command sets speaker volume to low, medium, or high Modulation Handshake This command turns the speaker on or offResult Code Control Return On-line to Data ModeSelect Pulse Dialing Result Code Option DCE Response FormatDial Tone Detect Extended Result CodesBusy Tone Detect Long space disconnect is always disabledLong Space Disconnect Recall Stored ProfileData Carrier Detect DCD Control Auto RetrainThis modem always auto retrains DTR Control Load Factory SettingsLocal Flow Control Selection Auxiliary Relay optionPulse Dial Make-to-Break Ratio Selection Asynchronous Communications ModeThis Command is effective only for use in Japan Data Set Ready DSR Option This command selects DSR actionBelow is an example of a possible output This command is used to display the active profilesSSE \Bn Zn=x\An Modem Port Flow Control Adjust Bits/s Rate Control\Kn \Nn Error Control Mode Selection = 0, 1, 2, 3, 4, 5 \Xn XON/XOFF Pass Through \Tn Inactivity Timer\Vn Protocol Result Code View Numbers in Blacklist Enable/Disable Data CompressionData Calling Tone Self-Test Commands AT Commands for Testing and DebuggingWrite to/Read from DSP Register Line-to-Line LoopbackATI11 Type Registers ReferenceRange 0−255 Default UnitsASCII Range 0−255 Default UnitsringsRange −127, Ascii decimal Default Carriage return Units Range −127, Ascii decimal Default Line feed UnitsRange Default Unitsseconds Range −32 Default Backspace UnitsConnection Completion Time-Out Comma Dial Modifier TimeS11 Dtmf Dialing Speed S10S12 Escape Guard Time S14 General Bit Mapped Options StatusS22 S24 Timer to Control Sleep ModeS21 S30 Inactivity Timer S28 Modulation Enable/DisableS32 S33S38 56K Dial Line Rate default S37 Dial Line Rate defaultS36 ConnectionS48 Lapm Error Control and Feature Negotiation default S42 Auto Rate default 1, rangeS43 Auto Mode default 1, range S90 S89 Timer to Control Sleep ModeS91 S92No Carrier S109K56flex and V.90 Selection defaultResult Code Declaration of Conformity Appendix B Communications RegulationsCanadian Department of Communications Cdoc