Actiontec electronic V.90 ISA Range 0−255 Default Unitsrings, Range 0−255 Default UnitsASCII

Page 61

S0

Auto Answer Ring Number

Range: 0−255

Default: 0

Units:rings

This register determines the number of rings the modem will count before automati- cally answering a call. Enter 0 (zero) if you do not want the modem to automatically answer at all. When disabled, the modem can only answer with an ATA command.

S1

Ring Counter

Range: 0−255

Default: 0

Units:rings

This register, Ring Counter, is read only. The value of S1 is incremented with each ring. If no rings occur over a six second interval, this register is cleared.

S2

AT Escape Character (user defined)

Range: 0−255

Default: 43

Units:ASCII

This register determines the ASCII valued used for an escape sequence. The default is the + character. The escape sequence allows the modem to exit data mode and enter command mode when on-line. Values greater than 127 disable the escape sequence.

S3

Command Line Termination Character (user defined)

Range:

0−127, ASCII decimal

Default:

13 (carriage return)

Units:

ASCII

This register determines the ASCII values as the carriage return character. This char- acter is used to end command lines and result codes.

S4

Response Formatting Character (user defined)

Range:

0−127, ASCII decimal

Default:

10 (line feed)

Units:

ASCII

This register determines the ASCII value used as the line feed character. The modem uses a line feed character in command mode when it responds to the computer.

61

Image 61
Contents ISA Plug n Play Voice/Fax Modem Table of Contents Contacting Actiontec Customer Support IntroductionBefore You Begin For Windows 95/98 InstallationFor Windows NT 4.0 Installation Hardware Installation Installing The ModemInstalling The Modem Connecting Devices Connecting Devices to the ModemConfiguring Windows Page Finish Configuring Windows 95 OSR2Page Page Configuring Windows Page Page Page Page Configuring Windows NT Page Page Page Page Fax TIA/EIA-578 for Class 1 Fax Voice Installing Communications SoftwareInit String AT&F&C1&D2W2Windows 95/98 TroubleshootingMore Info Panel No Dialtone Error Common ProblemsCommunications Software Does Not Work COM Ports and Interrupts Appendix a Non Plug-N-Play InstallationsJumper Settings Jumpers Set To Plug-N-Play default setting Hardware and Driver Installation Installing In DOS and WindowsRemove Page Repeat Last Command Appendix B AT Command SetAnswer Command ATXnCarrier Control Result CodesLast number dialed DnDialOnline Data Character Echo Command Echo CommandHook Control This command sets speaker volume to low, medium, or high Monitor Speaker VolumeRequest ID Information Modulation Handshake This command turns the speaker on or offSelect Pulse Dialing Return On-line to Data ModeResult Code Control Result Code Option DCE Response FormatDial Tone Detect Extended Result CodesBusy Tone Detect Long space disconnect is always disabledLong Space Disconnect Recall Stored ProfileThis modem always auto retrains Auto RetrainData Carrier Detect DCD Control DTR Control Load Factory SettingsLocal Flow Control Selection Auxiliary Relay optionThis Command is effective only for use in Japan Asynchronous Communications ModePulse Dial Make-to-Break Ratio Selection Data Set Ready DSR Option This command selects DSR actionBelow is an example of a possible output This command is used to display the active profilesSSE \An Zn=x\Bn Modem Port Flow Control Adjust Bits/s Rate Control\Kn \Nn Error Control Mode Selection = 0, 1, 2, 3, 4, 5 \Vn Protocol Result Code \Tn Inactivity Timer\Xn XON/XOFF Pass Through Data Calling Tone Enable/Disable Data CompressionView Numbers in Blacklist Self-Test Commands AT Commands for Testing and Debugging Write to/Read from DSP Register Line-to-Line LoopbackATI11 Type Registers ReferenceRange 0−255 Default UnitsASCII Range 0−255 Default UnitsringsRange −127, Ascii decimal Default Carriage return Units Range −127, Ascii decimal Default Line feed UnitsRange Default Unitsseconds Range −32 Default Backspace UnitsConnection Completion Time-Out Comma Dial Modifier TimeS11 Dtmf Dialing Speed S10S12 Escape Guard Time S14 General Bit Mapped Options StatusS21 S24 Timer to Control Sleep ModeS22 S30 Inactivity Timer S28 Modulation Enable/DisableS32 S33S38 56K Dial Line Rate default S37 Dial Line Rate defaultS36 ConnectionS43 Auto Mode default 1, range S42 Auto Rate default 1, rangeS48 Lapm Error Control and Feature Negotiation default S90 S89 Timer to Control Sleep ModeS91 S92No Carrier S109K56flex and V.90 Selection defaultResult Code Declaration of Conformity Appendix B Communications RegulationsCanadian Department of Communications Cdoc