Canon FB630U/FB636U manual How to Use this Guide, Where to Look

Page 3

How to Use this Guide

This guide explains how to use the Canon Plug-in Module CS-U 3.3 (herein referred to as Plug-in Module CS-U) with application programs supporting CanoScan FB630U/FB636U, such as Canon Photo.

A plug-in is used within a compatible application program like Canon Photo to expand its functionality and cannot be used as a stand-alone application. By only installing the Plug-in Module CS-U from the Canon Creative Image CD-ROM, Plug-in Module CS-U can be simply plugged into the parent program and add the ability to scan.

Before using Plug-in Module CS-U, we strongly recommend reading this guide and keeping this CD-ROM in a safe place for later reference.

Where to Look

Quick Start Instructions p. 9

The Quick Start Instructions is a brief summary of commands and procedures that will assist in using Plug-in Module CS-U immediately.

Scanning Preparations (Required Reading) p. 12

All users should read this section to learn the procedures for adjusting magnification and scan mode settings in preparation for scanning.

Scanning (Required Reading) p. 27

All users should read this section to learn the procedures for scanning and saving images.

Adjusting and Editing Scanned Images p. 33

Read this section for details about how to use Canon Photo to adjust image brightness, color tone, and other attributes. You can read this section according to your needs.

About the Conventions Used in this Guide

The following conventions are used in this guide to draw your attention to important information.

CAUTION:

This symbol is used to highlight procedural precautions and limitations.

Always read these topics to avoid errors.

HINT:

This symbol is used to present helpful hints and supplemental information.

Reading these topics is recommended to enhance your enjoyment of

Plug-in Module CS-U.

3

Image 3
Contents User’s Guide This page intentionally left blank How to Use this Guide Where to LookAbout the Conventions Used in this Guide Table of Contents Appendices Control Panel Features E P Scanning ProceduresSupports ColorSync 2.0 or higher Auto Tone Correction Plug-in Module CS-U Special FeaturesSee the Results of Adjustments Immediately Dynamic Preview Gamma Curve Adjusts Image BrightnessStart the Preview Scan Installing Plug-in Module CS-UQuick Start Instructions Start Plug-in Module CS-USelect the area to be scanned by clicking and dragging Set the preferences, magnification and scan mode settingsSpecify the Area of the Image to be Scanned p Click the Browser buttonFolder, file name and file format Scan the Image pClick the Scan button Save the image with the application software, specifying aE P E P Display Plug-in Module CS-U Control PanelCanon Photo E P Operating ProceduresPreviewing Set the original on the scanner document glassClick the Preview button Unit Set PreferencesE P Setting Basic Resolution E P Preview Window Size Preview Window Settings Dialog BoxSelect the Prefs menu in the control panel Return to Default SettingsProcedures E P CalibrationSet Magnification Output Device Resolution= 360 dpi, Magnification= 100%Set the desired magnification factor on the control panel E P To Set the Magnification FactorGrayscale Set Scan ModeBlack & White Diffusion DitherHigh Definition Color ColorSelect the scan mode that you want To Set the Scan ModeTo Verify the Image Verify Image Before ScanningE P Scanning Position the pointer in the preview window Scan Area SettingsZooming To ZoomSelect the area you want to enlarge with the zoom function To return to normal view, click the Zoom Out button Click the Zoom In buttonScanning To Initiate the ScanSpecify the Scan Area To Save an Image Saving Scanned ImagesDiffusion Dither Color/High Definition ModeGrayscale Mode Black & White ModeUsing the Histogram Feature to Adjust Image Contrast How to Interpret HistogramsHow to Adjust Histograms Click the OK button E P To Adjust a HistogramClick the Histogram button Click the Auto buttonSetting the Gamma Adjusting the Image with Gamma SettingsGamma Gamma =Brightness and Contrast Settings ContrastBrightness Click the Gamma button E P To Adjust the Brightness and ContrastCRT Type C Adjusting Gamma with the MenuCRT Type a CRT Type BClick the radio button for Menu Setting E P To Change the Gamma Value SettingsGamma Value Settings Adjusting the Gamma Value to Match the DisplaySending Output to a Printer Slider Manipulating the Graph Tone Curve SettingsE P To Edit the Tone Curve To Activate the ColorSync Function Auto Tone Correction ColorSyncProcedure DescreenOpen the Image menu and select Descreen Set the threshold value in the Control Panel To Set the Threshold ValueTo Save Settings in a Settings File Saving / Recalling SettingsE P To Recall a Settings File Many special effects may be achieved with filters Editing Scanned ImagesMatching Scan Resolution to Purpose Optical and Enhanced ResolutionsScanning Techniques Specifications Functional SpecificationsSystem Requirements Troubleshooting ProblemClicked on the Plug-in Module CS-U control panel Scan button cannot be selected Response Error MessagesError Message CauseGlossary Scanner ResolutionImage File PreviewIndex P E N D I C E S Mail support via Canon Computer Systems, Inc Canon Customer Care CenterOE-030AA 0799 CDS Canon Inc