Datalogic Scanning 1000I manual Table E-6. Japanese DOS Function Key Map

Page 153

Keyboard Model Cross Reference

Table E-6. Japanese DOS Function Key Map

ASCII value

ASCII code

Key

Scancode

 

 

 

 

00h

NUL

ALT right Make

31h

01h

SOH

ALT right Break

B1h

02h

STX

ALT left Make

31h

03h

ETX

ALT left Break

B1h

04h

EOT

CTRL left Make

41h

05h

ENQ

CTRL left Break

C1h

06h

ACK

CTRL right Make

41h

07h

BEL

CTRL right Break

C1h

08h

BS

BS

3Eh

09h

HT

TAB right

3Ch

0Ah

LF

RIGHT arrow (inner keypad)

4Dh

0Bh

VT

TAB left

3Ch + S

0Ch

FF

Enter (right keypad)

60h

0Dh

CR

CR

3Bh

0Eh

SO

INSERT (inner keypad)

52h

0Fh

SI

PAGE UP (inner keypad)

49h

10h

DLE

PAGE DOWN (inner keypad)

51h

11h

DC1

HOME (inner keypad)

4Ch

12h

DC2

LEFT arrow (inner keypad)

4Bh

13h

DC3

DOWN arrow (inner keypad)

4Ah

14h

DC4

UP arrow (inner keypad)

4Eh

15h

NAK

F6

6Dh

16h

SYN

F1

68h

17h

ETB

F2

69h

18h

CAN

F3

6Ah

19h

EM

F4

6Bh

1Ah

SUB

F5

6Ch

1Bh

ESC

ESC

3Dh

1Ch

FS

F7

6Eh

1Dh

GS

F8

6Fh

1Eh

RS

F9

70h

1Fh

US

F10

71h

Product Reference Guide

E-5

Image 153
Contents Magellan Datalogic Scanning, Inc Table of Contents Magellan Iii IBM USB Manual Conventions About This ManualAn approved A/C Adapter as shown in . For Connecting the ScannerResetting the Standard Product Defaults Using the Programming Bar CodesProgramming LED and Beeper Indicators Error Error CodesGetting Started Double Read Timeout General FeaturesGeneral Features Productivity Index Reporting PIR Label Gone TimeoutSleep Mode Minutes Power On Alert LED and Beeper IndicatorsGood Read When to Indicate Good Read Beep Frequency Good Read Beep ControlSpecifies the duration of a good read beep Good Read Beep LengthGood Read Beep Volume Scanning Features Target Mode Active TimeTargeted Scanning Mode Target Mode Linger Time Wake Up Intensity 13% 14% 15% Interface Related Features Keyboard Wedge Interface Reference Interface Selection Keyboard Wedge H Keyboard Wedge J ³ 0 0 0 1 3 B Interface Selection Obey/Ignore Host Commands Interface FeaturesHost Transmission Buffers Interface FeaturesRS-232 Interface Features Data Bits Hardware Flow Control Intercharacter Delay Software Flow Control Disables/Enables software control using XON/XOFF charactersHost Echo Host Echo Quiet Interval Signal Voltage Normal/TTL Beep on Ascii BEL RS-232 InvertBeep on Not on File ACK NAK Options RS-232 Interface Features cont. ACK CharacterNAK Character ACK NAK Timeout Value Retry on ACK NAK TimeoutACK NAK Retry Count ACK NAK Error Handling IBM-USB Interface Features Transmission Failure IndicationIBM-USB Device usage IBM Transmit Labels in Code 39 Format IBMSupported Symbologies Wand EmulationWand Emulation Bar Code Format Wand Idle State Bar/Space PolarityTransmit Trailing Noise Signal SpeedTransmit Leading Noise Symbology ConversionKeyboard Wedge USB Keyboard Keyboard Wedge Caps Lock State Power-On Simulation Vided for each available scancode set. Reference pings Wedge Quiet Interval Intercharacter Delay Please Keep In Mind Data Editing OverviewGlobal Prefix/Suffix Scan the END bar code to exit Programming ModeDefault Setting Suffix 0D CR AIM ID Label ID Position Options Label IDLabel ID Position Before Bar Code Data Default Setting for this Feature FF 4646 hex Default Setting for this Feature I 49 hex Default Setting for this Feature G8 4738 hex Default Setting for this Feature % 25 hex Case Conversion 41423132FFFFFFFF Character ConversionDisable/Enable UPC-A SymbologiesUPC-A Check Digit TransmissionExpand UPC-A to EAN-13 UPC-A Minimum Reads Number System TransmissionUPC-A In-store Minimum Reads UPC-E Disable/Enable UPC-EUPC-E Number System DigitExpand to UPC-E to UPC-A Minimum Reads Expand UPC-E to EAN13Expand UPC/EAN to Gtin GtinEAN-13 Disable/Enable EAN-13Isbn EAN-13 Flag 1 CharacterMinimum Reads EAN-8 Disable/Enable EAN-8EAN-8 Enable EAN Two-Label Add-ons Disable Optional 2-Digit Add-ons Disable/Enable RSS-14 RSS-14UCC/EAN 128 Emulation Minimum Reads RSS Expanded Disable/Enable RSS ExpandedLength Control RSS Expanded Length 1, Length 2 Programming Instructions Minimum Reads Disable/Enable Code CodeCheck Character Calculation Start/Stop Characters Check Character TransmitCode 39 Full Ascii Code Quiet Zones Code 39 Length 1, Length 2 Programming InstructionsCode 39 Stitching Pharmacode Disable/Enable PharmacodeCheck Character Transmit Transmit Function Characters Length Control Code 128 Conversion to Code Code 128 Length 1, Length 2 Programming InstructionsCode 128 Stitching Disable/Enable Interleaved 2 Interleaved 2Check Digit Calculation Check Digit Transmit Length Control Default Setting for this Feature Interleaved 2 of 5 Stitching Minimum Reads Disable/Enable Codabar CodabarCheck Character Verification Check Character Transmit Length Control Quiet Zones Codabar Length 1, Length 2 Programming InstructionsStart/Stop Character Transmission Start/Stop Character TypeCodabar Stitching Start/Stop Character MatchMinimum Reads Following options apply to the Code 93 symbology Length Control Code 93 Length 1, Length 2 Programming Instructions Code 93 Stitching Disable/Enable MSI/Plessey MSI/PlesseyCheck Digit Verification Number of Check Characters Length Control MSI/Plessey Length 1, Length 2 Programming Instructions MSI/Plessey Stitching Minimum Reads Standard 2 Disable/Enable Standard 2Check Digit Transmit Length Control Standard 2 of 5 Length 1, Length 2 Programming Instructions Standard 2 of 5 Stitching Minimum Reads Symbologies Optical and Read Performance Parameters Scanner DimensionsElectrical Parameters Physical PropertiesEnvironmental Parameters Other ParametersStandard Cable Pinouts Primary Interface Cables RS-232IBM Port 5B/9B/17 USB & USB Keyboard IBM USBAlpha-Numeric Pad Alpha-Numeric Pad Interface Default Exceptions Defaults by SymbologyRS-232 Wincor/Nixdorf IBM InterfacesKeyboards Magellan Keyboard Model Cross Reference Keyboard Function Key MappingsTable E-2. Scanset 1 Function Key Map Table E-4.Scanset 3, 102-Key Function Key Map Table E-5. Scanset 3 122-Key Function Key Map Table E-6. Japanese DOS Function Key Map Table E-7. NEC 9801-Key Function Key Map Accepting RS-232 Commands Host CommandsMagellan Sample Symbols Sample Symbols Ascii Chart Datalogic Scanning, Inc