Interface Related Features
Wand Emulation
Supported Symbologies
The Wand Emulation interface will transmit bar code data as a wand device would. This inter- face will transmit the following bar code symbologies:
•UPC/EAN
•UPC/EAN with addons
•Code 39
•Full ASCII Code 39
•Interleaved 2 of 5
•Codabar
•Code 128
Pharmacode 39 is transmitted as Code 39. All other bar code symbology types read by the scan- ner will be transmitted as Code 128.
Wand Emulation Bar Code Format
The following format settings are required for the wand emulation interface. These settings have been
•
•
•
•
•Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must NOT contain start / stop characters.
•Codabar bar codes must include the start / stop characters, presented in the ABCD for- mat.
•Interleaved 2 of 5 bar codes must have an even number of digits.