Datalogic Scanning 1000I Global Prefix/Suffix, Scan the END bar code to exit Programming Mode

Page 64

Data Editing

Enter prefixes and suffixes in the order in which you want them to appear on the output.

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated in Figure 4-2.

Figure 4-2. Prefix and Suffix Positions

OR...

Prefix

Label ID

AIM ID

Bar Code Data

Label ID

Suffix

00 - 20 Characters (ASCII)

AND

OR

Example: Setting a Prefix

In this example, we’ll set a prefix for all symbologies.

1.Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.

2.Scan the START bar code.

3.Scan the SET PREFIX bar code.

4.Reference the ASCII Chart on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from Appendix C, Alpha-

Numeric Pad.

5. Scan the END bar code to exit Programming Mode.

If less than the expected string of 20 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode.

NOTE

6.The resulting message string would appear as follows:

Scanned bar code data:12345

Resulting message string output: $12345

4-2

Magellan® 1000i

Image 64
Contents Magellan Datalogic Scanning, Inc Table of Contents Magellan Iii IBM USB About This Manual Manual ConventionsConnecting the Scanner An approved A/C Adapter as shown in . ForUsing the Programming Bar Codes Resetting the Standard Product DefaultsProgramming LED and Beeper Indicators Error Codes ErrorGetting Started General Features Double Read TimeoutGeneral Features Label Gone Timeout Productivity Index Reporting PIRSleep Mode Minutes LED and Beeper Indicators Power On AlertGood Read When to Indicate Good Read Beep Control Good Read Beep FrequencyGood Read Beep Length Specifies the duration of a good read beepGood Read Beep Volume Target Mode Active Time Scanning FeaturesTargeted Scanning Mode Target Mode Linger Time Wake Up Intensity 13% 14% 15% Interface Related Features Keyboard Wedge Interface Reference Interface Selection Keyboard Wedge H Keyboard Wedge J ³ 0 0 0 1 3 B Interface Selection Interface Features Obey/Ignore Host CommandsInterface Features Host Transmission BuffersRS-232 Interface Features Data Bits Hardware Flow Control Intercharacter Delay Disables/Enables software control using XON/XOFF characters Software Flow ControlHost Echo Host Echo Quiet Interval Signal Voltage Normal/TTL RS-232 Invert Beep on Ascii BELBeep on Not on File ACK NAK Options ACK Character RS-232 Interface Features cont.NAK Character Retry on ACK NAK Timeout ACK NAK Timeout ValueACK NAK Retry Count ACK NAK Error Handling Transmission Failure Indication IBM-USB Interface FeaturesIBM-USB Device usage IBM IBM Transmit Labels in Code 39 FormatWand Emulation Supported SymbologiesWand Emulation Bar Code Format Bar/Space Polarity Wand Idle StateSignal Speed Transmit Trailing NoiseSymbology Conversion Transmit Leading NoiseKeyboard Wedge USB Keyboard Keyboard Wedge Caps Lock State Power-On Simulation Vided for each available scancode set. Reference pings Wedge Quiet Interval Intercharacter Delay Data Editing Overview Please Keep In MindScan the END bar code to exit Programming Mode Global Prefix/SuffixDefault Setting Suffix 0D CR AIM ID Label ID Label ID Position OptionsLabel ID Position Before Bar Code Data Default Setting for this Feature FF 4646 hex Default Setting for this Feature I 49 hex Default Setting for this Feature G8 4738 hex Default Setting for this Feature % 25 hex Case Conversion Character Conversion 41423132FFFFFFFFSymbologies Disable/Enable UPC-ACheck Digit Transmission UPC-AExpand UPC-A to EAN-13 Number System Transmission UPC-A Minimum ReadsUPC-A In-store Minimum Reads Disable/Enable UPC-E UPC-ENumber System Digit UPC-EExpand to UPC-E to UPC-A Expand UPC-E to EAN13 Minimum ReadsGtin Expand UPC/EAN to GtinDisable/Enable EAN-13 EAN-13EAN-13 Flag 1 Character IsbnMinimum Reads Disable/Enable EAN-8 EAN-8EAN-8 Enable EAN Two-Label Add-ons Disable Optional 2-Digit Add-ons RSS-14 Disable/Enable RSS-14UCC/EAN 128 Emulation Minimum Reads Disable/Enable RSS Expanded RSS ExpandedLength Control RSS Expanded Length 1, Length 2 Programming Instructions Minimum Reads Code Disable/Enable CodeCheck Character Calculation Check Character Transmit Start/Stop CharactersCode 39 Full Ascii Code Code 39 Length 1, Length 2 Programming Instructions Quiet ZonesCode 39 Stitching Disable/Enable Pharmacode PharmacodeCheck Character Transmit Transmit Function Characters Length Control Code 128 Length 1, Length 2 Programming Instructions Code 128 Conversion to CodeCode 128 Stitching Interleaved 2 Disable/Enable Interleaved 2Check Digit Calculation Check Digit Transmit Length Control Default Setting for this Feature Interleaved 2 of 5 Stitching Minimum Reads Codabar Disable/Enable CodabarCheck Character Verification Check Character Transmit Length Control Codabar Length 1, Length 2 Programming Instructions Quiet ZonesStart/Stop Character Type Start/Stop Character TransmissionStart/Stop Character Match Codabar StitchingMinimum Reads Following options apply to the Code 93 symbology Length Control Code 93 Length 1, Length 2 Programming Instructions Code 93 Stitching MSI/Plessey Disable/Enable MSI/PlesseyCheck Digit Verification Number of Check Characters Length Control MSI/Plessey Length 1, Length 2 Programming Instructions MSI/Plessey Stitching Minimum Reads Disable/Enable Standard 2 Standard 2Check Digit Transmit Length Control Standard 2 of 5 Length 1, Length 2 Programming Instructions Standard 2 of 5 Stitching Minimum Reads Symbologies Scanner Dimensions Optical and Read Performance ParametersPhysical Properties Electrical ParametersEnvironmental Parameters Other ParametersRS-232 Standard Cable Pinouts Primary Interface CablesIBM Port 5B/9B/17 IBM USB USB & USB KeyboardAlpha-Numeric Pad Alpha-Numeric Pad Defaults by Symbology Interface Default ExceptionsIBM Interfaces RS-232 Wincor/NixdorfKeyboards Magellan Keyboard Function Key Mappings Keyboard Model Cross ReferenceTable E-2. Scanset 1 Function Key Map Table E-4.Scanset 3, 102-Key Function Key Map Table E-5. Scanset 3 122-Key Function Key Map Table E-6. Japanese DOS Function Key Map Table E-7. NEC 9801-Key Function Key Map Host Commands Accepting RS-232 CommandsMagellan Sample Symbols Sample Symbols Ascii Chart Datalogic Scanning, Inc