Siemens SPC3 manual System X86-Mode

Page 42

PROFIBUS Interface Center

SPC3

 

 

 

 

 

 

 

80286-System (X86-Mode)

Clock -Generator

48 MHz

12/24 MHz

DIVIDER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLK

 

 

 

 

 

 

 

 

Teiler

 

 

 

WR

 

 

XWR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XRD

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

RTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTR

 

 

X/INT

 

 

 

 

 

 

 

 

 

 

TxD

 

 

 

 

 

 

READY-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XREADY

 

 

 

 

 

 

Logic

 

 

 

 

 

RxD

 

 

 

 

80286

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

DB 7...0

DB

 

XCTS

 

 

 

 

Buscontr.

 

 

DB

DB 15...0

 

 

 

 

 

 

 

(7..0)

 

 

 

 

 

 

 

(82288) +

 

 

 

 

 

 

 

 

 

SPC3

 

 

 

82244

 

 

 

 

 

 

 

 

 

 

1K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AB

 

 

 

 

 

 

 

 

 

 

 

 

AB

AB 23...0

AB 12...1

 

 

 

GND

 

 

 

 

 

(10..0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD WR

Reset

Driver, Control-logic

EPROM

RAM

64kB

32kB

CSRAM

CSEPROM

Address Decoder

CS

SPC3

XCS Mode Reset

3K3

GND

Page 40

V1.3

SPC3 Hardware Description

2003/04

 

Copyright (C) Siemens AG 2003. All rights reserved.

Image 42
Contents Simatic NET Page SIM Atic NET Profibus Interface Center SPC3 Hardware DescriptionVersions Release Date ChangesDPBuffer Structure Description of the DP Services Mode RegisterStatus Register Interrupt Controller Watchdog Timer Directory11.3 Diagnostics Processing from the System View Asic TestPin Assignment Example for the RS 485 Interface SPC3 Introduction Function Overview Pin Description CmosCPD Cmos with pull down TTLt Schmitt trigger V1.3 Memory Allocation Memory Area Distribution in the SPC35FFH Segment Processor Parameters Latches/Register Significance Write Access OCH 0DH0EH 0FH Organizational Parameters RAM 1CH 1AH1BH 1DHMode Register Asic InterfaceDisstartcontrol Exiting the Offline state Mode Register 1 Mode-REG1, writableSTARTSPC3 EOIStatus Register Fdlindst Status Register Bit15 . .readableInterrupt Controller SPC3 IRR IMRDxout IMR IARBaud Rate Monitoring Watchdog TimerAutomatic Baud Rate Identification Response Time MonitoringPROFIBUS-DP Interface DPBuffer StructureUart RAM Aux-Buffer ManagementDescription of the DP Services SetSlaveAddress SAP55Sequence for the SetSlaveAddress Utility SetParam SAP61 Parameter Data StructureParameter Data Processing Sequence CheckConfig SAP62 SPC3Diagnostics Processing Sequence SlaveDiagnosis SAP60SPC3 Structure of the Diagnostics Buffer WriteReadData / DataExchange DefaultSAPWriting Outputs Reading Inputs UserWatchdogTimer GlobalControl SAP58GetConfig SAP59 ReadInputs SAP56ReadOutputs SAP57 General Description Hardware InterfaceUniversal Processor Bus Interface Bus Interface Unit BIUXINT/MO Mode Bus Interface V1.3Switching Diagram Principles Low Cost System with 80C32System X86-Mode SPC3 Application with the 80 CApplication with th 80 C Interface Signals UartAsic Test Permitted Operating Values Technical DataMaximum Limit Values DC-Specifikation of the I/O- DriversAC-Specification for the Output Drivers Tabel 8.3 DC-Specifikation of the I/O- DriversCurrent Tabelle 8.5 Leakage current of the output drivers Clock pulse 48 Mhz Timing CharacteristicsSYS Bus Interface Clock Pulse TimingST-Vers Min Max Unit ResetTiming in the Synchronous C32-Mode TBDSynchronous Intel-Mode, Processor-Read-Timing Synchronous Intel-Mode, Processor-Write-TimingTiming in the Asynchronous Intel Mode X86 Mode ST-VersParameter Min Max Asynchronous Intel-Mode, Processor-Write-Timing Asynchronous Intel-Mode, Processor-Read-TimingXRD XCS Xready XWR XCS4.1 74.2 Synchronous Motorola-Mode, Processor-Read-TimingSynchronous Motorola-Mode, Processor-Write-Timing Timing in the Asynchronous Motorola-Mode for example, 68HC16Asynchronous Motorola-Mode, Processor-Read-Timing XCS XdsackAsynchronous Motorola-Mode, Processor-Write-Timing Serial Bus Interface Pulse 48 MHzHousing PQFP-44 Housing SPC3 Hardware Description 13.90 Symbol Min Typ Max AMI-Vers13.65 14.15RTS Profibus InterfacePin Assignment TXDExample for the RS 485 Interface SN65ALS1176Profibus User Organisation AppendixAddresses Technical contact person at ComDeC in Germany10.3.1 SPC3 AMI General Definition of TermsOrdering of ASICs 10.3.2 SPC3 STIntroduction Appendix a Diagnostics Processing in Profibus DPDiagnostics Bits and Expanded Diagnostics StatdiagIdentifier Byte 7 has Etc Identifier Byte 0 has Simatic S5 / COM ET Diagnostics Processing from the System ViewSingle Diagnostics CombiAppendix B Useful Information Data format in the Siemens PLC SimaticPage Siemens Aktiengesellschaft

SPC3 specifications

Siemens SPC3 is a state-of-the-art solution designed to enhance industrial automation, providing businesses with a robust platform for managing complex processes efficiently. This device epitomizes Siemens' commitment to innovation, blending cutting-edge technology with user-friendly features to deliver optimized performance across various applications.

One of the standout features of the Siemens SPC3 is its advanced processing capabilities. Equipped with high-performance processors, it can handle various tasks simultaneously, ensuring seamless operation even in demanding environments. This performance is complemented by enhanced memory capacity, which allows for increased data handling and improved execution speed, crucial for real-time monitoring and control applications.

The Siemens SPC3 also integrates a modular design, enabling flexibility and scalability. This characteristic allows users to customize their systems according to specific operational needs, adding or removing components as required. This adaptability is particularly beneficial for businesses that aim to scale their operations without incurring the substantial costs associated with overhauling existing systems.

Furthermore, the SPC3 employs the latest communication technologies, ensuring interoperability with various devices and systems. It supports industry-standard protocols, facilitating efficient data exchange between components. This connectivity is vital for establishing smart factories and enhancing overall productivity by creating a unified ecosystem.

Another significant aspect of the Siemens SPC3 is its focus on security. As cyber threats in industrial settings become increasingly sophisticated, Siemens prioritizes safeguarding user data and system integrity. The SPC3 incorporates advanced security features, including encryption and access control measures, to protect against unauthorized access and ensure data confidentiality.

Siemens has also emphasized ease of use in the SPC3. The interface is designed to be intuitive, allowing operators to navigate and configure the system effortlessly. Coupled with comprehensive software tools, users are empowered to implement changes swiftly while minimizing downtime.

In terms of energy efficiency, the SPC3 incorporates technologies that allow for optimized energy consumption, aligning with sustainability goals prevalent in today’s industries. By reducing energy waste, businesses not only lower operational costs but also contribute to environmental conservation.

In summary, Siemens SPC3 represents a significant advancement in industrial automation technology. Its high-performance processing, modular adaptability, advanced communication capabilities, robust security measures, and user-friendly design make it an ideal choice for businesses striving for efficiency and innovation in their operations. The SPC3 is more than just a control device; it is a comprehensive solution that meets the evolving demands of modern industries.