Planar UR8450-MX, UR8450-LX, UR8450-3D manual Environmental Specifications

Page 92

LCD Optical Specifications (Continued)

Specification

Maximum

Minimum

Typical

 

 

 

 

Viewing Angle

 

 

 

2D content

 

89° in all directions

 

3D content left/right

 

89° in all directions

 

3D content up/down

 

26° combined

30° combined

 

 

 

 

Color gamut

 

 

72% NTSC

 

 

 

100% REC709

 

 

 

 

Red (x,y)

 

 

0.645, 0.335

Green (x,y)

 

 

0.300, 0.620

Blue (x,y)

 

 

0.150, 0.060

White (x,y)

 

 

0.279, 0.292

 

 

 

 

Native color temperature

 

 

10,000K

 

 

 

 

Number of colors

 

 

1 billion

 

 

 

 

Native resolution

 

 

3840 x 2160

 

 

 

 

Environmental Specifications

Specification

Maximum

Minimum

Optimal

Notes

 

 

 

 

 

Temperature

 

 

 

 

operating

40° C

0° C

20-25° C

All performance specifications are

 

104° F

32° F

 

maintained within this temperature range.

 

 

 

 

 

non-operating

60° C

–20° C

20° C

 

 

140° F

–4° F

+/- 10° C

 

 

 

 

 

 

Altitude (barometric pressure)

3000m

 

 

 

 

 

 

 

 

Humidity

 

 

 

 

operating

85% R.H.

 

 

non-condensing

non-operating

90% R.H.

 

 

non-condensing

 

 

 

 

 

Low line voltage range

 

 

100-120V

 

 

 

 

 

 

High line voltage range

 

 

200-240V

 

 

 

 

 

 

Line frequency range

 

 

49-61Hz

 

 

 

 

 

 

Acoustic Noise

 

 

 

Fanless

 

 

 

 

 

Inrush current

 

 

60A

 

 

 

 

 

 

Power consumption

 

 

 

 

Standby

 

 

< 0.5W

 

Normal operation

550W

 

465W typ.

550W x 3.42 BTU = 1881 BTU/hr max.

 

 

 

 

465W x 3.42 BTU = 1590 BTU/hr typ.

 

 

 

 

 

86

Planar UltraRes User Manual

Image 92
Contents Page Warranty and Service Plans RoHS Compliance Statement Table of Contents Connecting the Wired IR Module Remote Monitoring Software Setup Upgrading Network Firmware Symptom Can’t Get PC to Output 4K @ 24/30Hz Introduction Important Safety Instructions Page European Union Disposal Information Recommended Usage Burn-In Versus Temporary Image RetentionNormal Use Thermal Guidelines Cooling RequirementsBasic Concept of Planar UltraRes Display Using the Remote Control Powering On/Off Planar UltraRes Displays Planar UltraRes in Standby Mode Supported Formats for Single Inputs Input SetupSupported Formats for Multiple Inputs Input Setup Installing a Planar UltraRes Display Plan Your InstallationBefore You Begin Tools/Equipment ListSupported Graphics Cards Setting Up AMD Graphics Cards For 3D Content Setting Up Nvidia Graphics Cards Recommended PCsUnpacking and Checking Accessories LCD Module BoxKickstand Mounts to the display when Bracket Accessory Kit Following items are included in the accessory kitUnpacking and Checking Accessories LCD Installation Installing an UltraRes Display on a Wall Page Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Using the Kickstand Bracket Connections Connecting AC PowerConnecting the Wired IR Module Connecting Sources Setting Up UltraRes Using Multiple Inputs Using UltraRes Control Software to Set Up Multiple Inputs Connections Setting Up UltraRes Using Single Inputs Selecting Individual Inputs Using the Remote Control Connections Connections Installing the UltraRes Control Software Page Page Installing USB Drivers Using the UltraRes Control Software Model name Serial number Setting Up Sources Auto Power Off Timer Standby ModeTurning Local Dimming On or Off Changing Frame DelayChanging Backlight Intensity Upgrading Firmware Upgrading Firmware Upgrading Firmware Error Codes Error Codes Network Settings Dhcp Network SetupDhcp Network Setup Static IP Network Setup Open Network and Sharing Center Static IP Network Setup Static IP Network Setup Planar UltraRes Remote Monitoring Software Remote Monitoring HomeRemote Monitoring Unit Status Remote Monitoring Display ControlRemote Monitoring Power On/Off Remote Monitoring Source Setup Remote Monitoring Advanced Setup Remote Monitoring Admin SetupRemote Monitoring Network Setup Remote Monitoring Network Setup Remote Monitoring Date and Time Use this page to change date and time information as neededRemote Monitoring Access Control Remote Monitoring Software Setup Upgrading Network Firmware Remote Monitoring Reboot Remote Monitoring Reboot External Control RS232 Communication Connecting the RS232 CableSetting Up Multiple Inputs Using RS232 Commands Setting Up Single Inputs Using RS232 Commands RS232 Commands RS232 Command FormatRS232 Response Format Uwwwx=z CRRS232 Command/Response Examples Supported UltraRes RS232 Commands Setting Command Read Min Max String?MI1 Setting Snmp Monitoring Object Name Description ValueSending RS232 Commands Via UDP Using Discrete IR Codes IR Command ProtocolSupported UltraRes IR Commands Remote Control Address Data NEC Data From RemoteUsing Discrete IR Codes Specifications LCD Module SpecificationsEnvironmental Specifications Signal Compatibility Compatible Video SourcesSignal Compatibility UltraRes Dimensions Display Dimensions Front, Side and Top ViewsDisplay Dimensions Rear View Rear View Wall Mount Hangers and Service Panel Locations Landscape Wall Mounts Front and Bottom Views Landscape Wall Mounts Sides Views Portrait Wall Mounts Front View Portrait Wall Mounts Sides Views Optional Pedestal Mount Front View Optional Pedestal Mount Top and Bottom Views Optional Pedestal Mount Single and Double Sided Optional Pedestal Mount Double Sided in Service Position 100 Troubleshooting During Installation UltraRes LED CodesError Codes in the UltraRes Control Software Error Code MeaningEeprom Symptoms, Possible Causes and Solutions Symptom Can’t Get PC to Output 4K @ 24/30HzSymptom Can’t Get PC to Output 4K @ 60Hz Symptom IR Isn’t Working Properly Accessing Planar’s Technical Support Website Downloading Utility Software Regulatory Information 110 Index Using, 82 IR commands Network setup Index