Planar UR8450-MX, UR8450-LX, UR8450-3D manual Snmp Monitoring, Object Name Description Value

Page 86

SNMP Monitoring

SNMP Monitoring

The current settings and status of UltraRes units can be remotely monitored using SNMP (Simple Network Management Protocol), if the SNMP option is enabled through the web browser settings. The MIB (Management Information Base) used for all Planar display products is available by electronic distribution in the file PLANAR- DISPLAY-MIB.txt. The table below shows the objects that can be monitored – all Planar SNMP objects are read-only, and no traps are used. The default read-only community string for all Planar SNMP objects is “public”. Once the PLANAR-DISPLAY- MIB is loaded in your SNMP manager, you can walk all the available objects from the top-level object PlanarSystems(1.3.6.1.4.1.19125) or its sub-object PlanarDisplayProduct(1).

Most object values are integer type, except where noted. Generally, for integer types, the value -1 is returned if there is any internal system or communication error, and normal return values are zero or positive integers.

Object Name

Description

 

Value

 

 

 

plnrModel

Model name (string)

UltraRes

 

 

 

plnrSWPart

Part number (string) for the

010-01412

 

Remote Monitoring software

 

 

 

 

 

 

plnrSN1

Serial number (string)

 

 

 

 

 

 

plnrVersion1

SNMP agent version (string)

 

 

 

 

 

plnrVersion2

Firmware version (string)

See RS232 code “IFV”

 

 

 

plnrVersion3-6

FPGA 1-4 version (string)

See RS232 code “IF1” through “IF4”

 

 

 

 

plnrDisplayStatus

General display status

0

= Error

 

 

1

= OK

 

 

-1 = N/A

 

 

 

 

plnrPowerStatus

Power status information

0

= Power off or error

 

 

1

= OK

 

 

-1 = N/A

 

 

 

plnrDisplayBacklight

Backlight value

1-15. See RS232 code “BKL”

 

 

 

plnrDisplayColorSpace

User-selected color space

0-4. See RS232 code “CLS”

 

 

 

plnrInputSelect

User-selected input source

0-7. See RS232 code “INS”

 

 

 

 

plnrInputStatus

Input source status

0

= source absent

 

 

1

= source present

 

 

 

plnrInputHResolution

Horizontal resolution

Pixels

 

 

 

plnrInputVResolution

Vertical resolution

Pixels

 

 

 

plnrInputVRefresh

Vertical refresh rate

Hz x 100

 

 

 

plnrInputPixelClock

Dot clock value

MHz x 100

 

 

 

plnrTemp1

Internal temperature sensor value

Degrees C. See RS232 code “ITS”

 

 

 

 

80

Planar UltraRes User Manual

Image 86
Contents Page Warranty and Service Plans RoHS Compliance Statement Table of Contents Connecting the Wired IR Module Remote Monitoring Software Setup Upgrading Network Firmware Symptom Can’t Get PC to Output 4K @ 24/30Hz Introduction Important Safety Instructions Page European Union Disposal Information Recommended Usage Burn-In Versus Temporary Image RetentionNormal Use Thermal Guidelines Cooling RequirementsBasic Concept of Planar UltraRes Display Using the Remote Control Powering On/Off Planar UltraRes Displays Planar UltraRes in Standby Mode Supported Formats for Single Inputs Input SetupSupported Formats for Multiple Inputs Input Setup Before You Begin Installing a Planar UltraRes DisplayPlan Your Installation Tools/Equipment ListSupported Graphics Cards Setting Up AMD Graphics Cards For 3D Content Setting Up Nvidia Graphics Cards Recommended PCsUnpacking and Checking Accessories LCD Module BoxKickstand Mounts to the display when Bracket Accessory Kit Following items are included in the accessory kitUnpacking and Checking Accessories LCD Installation Installing an UltraRes Display on a Wall Page Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Installing an UltraRes Display on a Wall Using the Kickstand Bracket Connections Connecting AC PowerConnecting the Wired IR Module Connecting Sources Setting Up UltraRes Using Multiple Inputs Using UltraRes Control Software to Set Up Multiple Inputs Connections Setting Up UltraRes Using Single Inputs Selecting Individual Inputs Using the Remote Control Connections Connections Installing the UltraRes Control Software Page Page Installing USB Drivers Using the UltraRes Control Software Model name Serial number Setting Up Sources Auto Power Off Timer Standby ModeTurning Local Dimming On or Off Changing Frame DelayChanging Backlight Intensity Upgrading Firmware Upgrading Firmware Upgrading Firmware Error Codes Error Codes Network Settings Dhcp Network SetupDhcp Network Setup Static IP Network Setup Open Network and Sharing Center Static IP Network Setup Static IP Network Setup Planar UltraRes Remote Monitoring Software Remote Monitoring HomeRemote Monitoring Unit Status Remote Monitoring Display ControlRemote Monitoring Power On/Off Remote Monitoring Source Setup Remote Monitoring Advanced Setup Remote Monitoring Admin SetupRemote Monitoring Network Setup Remote Monitoring Network Setup Remote Monitoring Date and Time Use this page to change date and time information as neededRemote Monitoring Access Control Remote Monitoring Software Setup Upgrading Network Firmware Remote Monitoring Reboot Remote Monitoring Reboot External Control RS232 Communication Connecting the RS232 CableSetting Up Multiple Inputs Using RS232 Commands Setting Up Single Inputs Using RS232 Commands RS232 Commands RS232 Command FormatRS232 Response Format Uwwwx=z CRRS232 Command/Response Examples Supported UltraRes RS232 Commands Setting Command Read Min Max String?MI1 Setting Snmp Monitoring Object Name Description ValueSending RS232 Commands Via UDP Using Discrete IR Codes IR Command ProtocolSupported UltraRes IR Commands Remote Control Address Data NEC Data From RemoteUsing Discrete IR Codes Specifications LCD Module SpecificationsEnvironmental Specifications Signal Compatibility Compatible Video SourcesSignal Compatibility UltraRes Dimensions Display Dimensions Front, Side and Top ViewsDisplay Dimensions Rear View Rear View Wall Mount Hangers and Service Panel Locations Landscape Wall Mounts Front and Bottom Views Landscape Wall Mounts Sides Views Portrait Wall Mounts Front View Portrait Wall Mounts Sides Views Optional Pedestal Mount Front View Optional Pedestal Mount Top and Bottom Views Optional Pedestal Mount Single and Double Sided Optional Pedestal Mount Double Sided in Service Position 100 Troubleshooting During Installation UltraRes LED CodesError Codes in the UltraRes Control Software Error Code MeaningEeprom Symptoms, Possible Causes and Solutions Symptom Can’t Get PC to Output 4K @ 24/30HzSymptom Can’t Get PC to Output 4K @ 60Hz Symptom IR Isn’t Working Properly Accessing Planar’s Technical Support Website Downloading Utility Software Regulatory Information 110 Index Using, 82 IR commands Network setup Index