Casio AX200 manual DTU Operation, DTU LED Indicators

Page 107

www.axxessid.com

Installation & User Guide

7

DTU Operation

1.Start the AX200 software on the PC.

2.Connect the DTU to the serial port on the PC.

3.The auto detect hardware device wizard will start within 10 seconds.

4.Follow the on-screen prompts to add the DTU into the software.

5.Remove the DTU from the PC and plug into a controller.

6.Wait 10 seconds

7.Remove the DTU from the controller and plug it back into the PC.

8.The auto detect hardware device wizard will start within 10 seconds.

9.Follow the on-screen prompts to add the controller.

10.Click on the cardholder button and add new cards as required.

11.Upon exiting the cardholder screen, the new cards will automatically be downloaded to the DTU.

12.Click OK and wait for the on-screen message for the download to be completed.

13.Remove the DTU from the PC and plug it into the controller.

14.When the cards have been transferred from the DTU to the controller, the LED on the DTU will turn green.

15.Remove the DTU from the controller and plug it into the PC.

16.The software will report that the download has been completed successfully.

DTU LED Indicators

Blue

DTU Power OK

 

 

 

Blue/Red Flashing

No Communication

 

 

 

Red

Flashing

Wait

 

 

Constant

Error

 

 

 

Orange

Data download in progress

 

 

 

 

Flashing

Data downloaded to this controller –

 

data to be downloaded to others

Green

 

 

Constant

Data downloaded and complete

 

 

 

AX200 Installation & User Guide – July 2007

1 0 7

Image 107
Contents AX200 & i-BOX Email info@axxessid.com C e n s e a g r e e m e n t N t e n t s Photo Photo ID Add a Photo Rollback 109 103105 108AX200 Software Setup 2 0 0 InstallationInstallation & User Guide Installation & User Guide IP Address D e f i n i t i o n s a p p l i c a b l e t o t h e a X 2 02 0 0 & i B O X C o n n e c t i o n s WAN ConfigurationSounder /Beacon for i-BOX IC-ASB AX200 Expander Board Connections Breakglass Wiring AX200 Break glass Wiring AX200AX50 / AX100 Break glass wiring AX50/AX100Installation & User Guide Installation & User Guide Operating Systems F t w a r e Installation2 0 0 S o f t w a r e Installation & User Guide Installation & User Guide A r t i n g t h e a X 2 0 0 S o f t w a r e Windows Classic or Graphic Style XP Screen Password ReminderLanguage Selection C k u p & R e s t o r e Email Backup Settings Standard Query Language SQL Communication between the AX200 Software and Controller Database Integrity CheckPlug & Play Devices N t r o l l e r S t a t u s & C o n t r o l High Security Mode HSMOn & Offline Operation Door Unlock ModeDate and Time Performance Analyzer Force Download & Clear ControllerTransaction Screen Who’s In/Out List Photo Display Display FiltersInstallation & User Guide Test Wizard Save on ExitInstallation & User Guide Installation & User Guide Installation & User Guide Installation & User Guide Card Number Main SettingsR d h o l d e r Department Access GroupImprint Number EmploymentInstallation & User Guide Photo ID PhotoCapture Picture from Camera Add a PhotoAdd New Card Wizard Import Picture from FileTemplates Card Replacement Wizard Card Diagnostics Search Database Fields per Cardholder Main Settings TabCard 0 Function Print Current Card DetailsOther Info Employer Mode Settings Extended Door Open Time Ext’d Door Set High Security Mode Set Hi SecPersonal Info High Security Hi SecVehicle info C e s s P o i n t C o n f i g u r a t i o n Access Point SettingsAccess Identity Access Point NameDoor Comments Door Release Time Start-up Mode SettingsDoor Contact Settings PIN Settings Hardware Version Device ParametersDevice Group Device TypeSerial Number in Batch Access GroupsFirmware Version Batch NumberDevice Manager Creating a new access groupAutomatic IP Setup Installation & User Guide Device Status Indication Installation & User Guide Device Settings Test Connection Fire alarmSite Info S t e m S e t t i n g sTest Wizard Mail Unknown Format to Axxess ID Mail FacilitiesCompact Database DB MaintenanceFirmware Settings Rollback Hidden FunctionsInstallation & User Guide General Settings Link Alive Retry Times Function SettingsCOM Port Settings Multiple/Single Card Format Select COM PortR m a t & S t a t i s t i c s Default Access LevelDefault Time Zone DefaultFacility Code Card Type InformationCard Matching Card Format Analyzer & Format ConfigurationC u r i t y S e t t i n g s Adding a New Authorisation Group Adding a New UserP o r t Cardholder Brief Dossier Cardholder DetailsLog File System Summary Work SpellOperators EnvironmentalDestination PrintingFormat Types Door Panel Position Sensor V i r o n m e n t BOX Parameters Sensor SettingsAlarms Shunt alarm on delay BOX SettingsAccumulation Period PDU Power Distribution UnitDetails Power feed group Normal Power switched on, power sensed LED on solid Hardware Connection Details SensorIsolate PIR Installation & User Guide Dust Particle Sensor Mains Present Sensor U D a t a T r a n s f e r U n i t Connecting the DTU Installation & User Guide Add a New Door using a DTU DTU Step by Step Adding Card Formats using a DTUDTU Operation DTU LED IndicatorsClear DTU M o v i n g t h e a X 2 0 0 P r o g r a mT i V i r u s Installation & User Guide Fingerprint Reader A d e r sConfiguring Verid+ Programming a New User Getting Started Quickly Proximity Readers Installation & User Guide Output Type AXM ReadersProximity Request to Exit