MODEL: WD-52527 / WD-52528 / WD-62527 / WD-62528
SERVICING THE LENTICULAR SCREEN AND FRESNEL LENS
CAUTION: Wear gloves when handling the Lenticular Screen and Fresnel Lens.
This prevents cuts and finger prints. Do not place Fresnel Lens in the sun. This may cause fire and heat related injuries.
Lenticular Screen and Fresnel Lens Removal
1.Remove the screen assembly as shown in the Cabinet Disassembly procedure.
2.Remove the four screws (a) to remove the bottom of the
3.From the front of the screen assembly, slide the BEZEL out the bottom of the Screen Frame. (Figure 2)
4.From the rear of the screen assembly, carefully slide the Lenticular Screen and Fresnel Lens combination from the Screen Frame. (Figure 3)
Note: When separating the Lenticular Screen from the Fresnel Lens, use caution while prying the Screen and Lens apart. Use a slot type screw driver, and remove the pressure sensitive double sided tape.
Figure 1: SCREEN-FRAME-BOTTOM Removal (Rear View)
Page 22