|
| Tact 2.2X Room Correction Software |
|
| |
| Connect your | Your RCS 2.2X must be connected to your computers serial port in order for it to |
| RCS 2.2X to your | communicate with your computer and to run the Quick Setup and correction pro- |
| Computer | cess. Please follow the steps below to connect your |
|
| 1 - Connect the RS 232 “Input” jack on the back of the RCS 2.2X to your |
|
| computers serial port using the supplied cables and adapters. Your |
|
| computer must have a standard RS 232 serial port with a DB 9 connector. |
|
| NOTE: If you have any Tact digital amplifiers please disconnect their RS232 con- |
|
| nection at this time. |
|
| 2 - Turn on your RCS 2.2X. |
|
| 3 - Turn on your computer and start the Tact 2.2X Correction System |
|
| Software. |
|
| NOTE: You may receive a communication error message. Please close the |
|
| message window and proceed to the next step. |
|
| 4 - Select the “Communication” button on the main software screen to open |
|
| the communication window. |
|
| 5 - Under the Operating Mode select “Connect”. |
|
| 6 - Under the COM Port section select “COM1”. If you receive an “invalid |
|
| port number” message please try selecting each of the port selections until |
|
| you do not receive this message. If you receive this message on all COM ports |
|
| you may not have a COM port installed on your computer. Please refer to your |
|
| computer manufactures documentation for help to install a COM port. |
|
| 7 - To verify that RCS 2.2X is properly connected to the host computer click |
|
| on the “Start” button to perform the communication test. If everything is |
|
| functioning properly you should see the results below. Press the “Stop” |
|
| button after about 15 seconds to stop the test. |
|
| Rx Buf should display “0”. |
|
| Count should have counted in increments of 100. |
|
| Err Count should be “0”. |
|
| If the results are as above select the “Close” button to close the |
|
| communication window. Your RCS 2.2X is now connected to your computer. |
|
| If the results are not as above please go back to step number 6 and select |
|
| another COM port. Then repeat step 7. |
|
| NOTE: If you are still are not passing the communication test you may not have a |
|
| COM port installed on your computer or you may have another device such as a |
|
| modem or hand held PC that may be sharing the COM port on your computer. If |
|
| you have a Tact amplifier attached it may be set to the same address. The RCS re- |
|
| quires a valid COM port that is not being used by any other devices. |
|
| NOTE: You will only have to select the communication port once. The next time |
34 Tact Audio | you run the Tact 2.2X software it will remember your settings. |