1.GENERAL INFORMATION

The THCD-100 is a multi featured process display controller, capable of interfacing directly to a mass flow meter, mass flow controller or another process transducer such as the THPS-760S Vacuum Transducer. The THCD-100 is a single channel unit which can be used to power a bipolar (±15dc @ 250mA) device and/or display the output from a transducer that supplies voltage signals up to 10 VDC. There is also an input that can be used for external command (setpoint) control (+5v full scale). Digital interfaces to the THCD-100 include RS485 and RS232.

1.1.Features

16-bit Resolution

±0.2% Reading + 1 Digit Accuracy

0-5 Volt Set Point Via Front Panel Or Digitally (RS232/RS485) Dual Programmable Alarms with Relays

RS232/485 and Analog Output (Standard) CE Approved

1.2.Specifications

For a list of specifications, please see the PB-185_rev-0711_THCD-100 Power Supply.

165-072011 THCD-100 Power Supply

Page 4 of 28

Image 4
Contents Teledyne Hastings Manual Print History Table of Contents Specifications FeaturesGeneral Information Transducer socket Pinout 15 Pin D Type InstallationPin Number Designation Interface Socket Pin out Miniature 15 Pin D Type InterfaceSerial Socket Pinout 9 Pin D Type Pin Number Designation 1Power Connection Socket Panel MountingFeatures IntroductionAnalog Inputs Analog OutputsSetpoint Mode User Re-zeroAdaptive Filtering Setpoint SourceFilter Size Common Switch Functions Edit ModeMenu Screens Editable ScreensSwitch Functions Front Panel ScreensMain Screen not changing setpoint Main Screen changing setpointMain Menu Screen Switch FunctionsSetpoint Screen Input Screen Filtering ScreenComms Menu Screen Serial ScreenFactory Defaults Confirmation Screen Relay ScreenCommand/Query Format Serial CommunicationOutput Current Readings ‘r’ Main CommandsOutput Current Readings Repeatedly ‘rp’ Setpoint Mode ‘spm’ Setpoint Value ‘spv’Setpoint Source ‘sps’ Setpoint Initial Value ‘siv’Serial Commands Setpoint Initial Mode ‘sim’Serial Baud Rate ‘bra’ Serial Communication Protocol ‘pro’Channel Setup Commands Filtering CommandsRelay Control Commands Filter Size ‘fls’Relay Trip Point ‘rlt’ Relay Hysteresis ‘rlh’Other Commands Retrieve All Settings ‘ras’User Input Re-zero ‘irz’ Date of Last Factory Calibration ‘dlc?’Service & Calibration ServiceCleaning End of LifeAppendices Appendix aSetting Default Value Additional Information Appendix BAppendix C Settings in ‘ras’ command stringDescription Type and size Warranty Repair Policy WarrantyNon-Warranty Repair Policy