Teledyne THCD-100 Appendix C, Settings in ‘ras’ command string, Description Type and size

Page 27

7.3.Appendix C

Table 3 – Settings in ‘ras’ command string

Description

Type and size

 

 

Input channel units string

5 char string

 

 

range

8 char string representation of a float

 

full scale

8 char string representation of a float

 

 

Setpoint value

8 char string representation of a float

 

 

slave value

8 char string representation of a float

 

 

mode

1 byte (02 as for spm? query)

 

 

source

1 byte (01 as for sps? query)

 

initial value

8 char string representation of a float

 

 

initial slave value

8 char string representation of a float

 

 

initial mode

1 byte (02 as for sim? query)

 

 

Adaptive filter band

4 char string representation of a float

 

 

size

1 byte (06 as for fls? query)

 

 

Relay 1 trip point

8 char string representation of a float

 

 

hysteresis value

4 char string representation of a float

 

 

Relay 2 trip point (if factory fitted)

8 char string representation of a float

 

 

hysteresis value (if factory fitted)

4 char string representation of a float

 

 

Last factory calibration date

6 char string (format as for dlc? query)

 

 

165-072011 THCD-100 Power Supply

Page 27 of 28

Image 27
Contents Teledyne Hastings Manual Print History Table of Contents Features SpecificationsGeneral Information Installation Transducer socket Pinout 15 Pin D TypePin Number Designation Pin Number Designation 1 Interface Socket Pin out Miniature 15 Pin D TypeInterface Serial Socket Pinout 9 Pin D TypePanel Mounting Power Connection SocketAnalog Outputs FeaturesIntroduction Analog InputsSetpoint Source Setpoint ModeUser Re-zero Adaptive FilteringFilter Size Editable Screens Common Switch FunctionsEdit Mode Menu ScreensMain Screen changing setpoint Switch FunctionsFront Panel Screens Main Screen not changing setpointSwitch Functions Main Menu ScreenSetpoint Screen Filtering Screen Input ScreenSerial Screen Comms Menu ScreenRelay Screen Factory Defaults Confirmation ScreenSerial Communication Command/Query FormatMain Commands Output Current Readings ‘r’Output Current Readings Repeatedly ‘rp’ Setpoint Initial Value ‘siv’ Setpoint Mode ‘spm’Setpoint Value ‘spv’ Setpoint Source ‘sps’Serial Communication Protocol ‘pro’ Serial CommandsSetpoint Initial Mode ‘sim’ Serial Baud Rate ‘bra’Filtering Commands Channel Setup CommandsRelay Hysteresis ‘rlh’ Relay Control CommandsFilter Size ‘fls’ Relay Trip Point ‘rlt’Date of Last Factory Calibration ‘dlc?’ Other CommandsRetrieve All Settings ‘ras’ User Input Re-zero ‘irz’End of Life Service & CalibrationService CleaningAppendix a AppendicesAppendix B Setting Default Value Additional InformationSettings in ‘ras’ command string Appendix CDescription Type and size Warranty Warranty Repair PolicyNon-Warranty Repair Policy