Configuring the RC/GS and RC7
The generator can be started or stopped at any time by pressing the down arrow button until the Gen Start/Stop menu is displayed. Press and hold the On/Off button until you hear a beep from the RC/GS. Release the button after the beep sounds.
If the inverter/charger senses an AC supply and the battery voltage is below the automatic start setting, the generator does not start. When you start the generator with the On/Off button, the generator starts even if an AC supply is present.
Important: If the generator is manually started from the remote, a manual override is initiated and the generator will not stop automatically. Shut down the generator manually.
On / Off | Gen Start/Stop |
| |
| Press (ON/OFF) |
Figure 3-13 Generator Start/Stop
Generator Stop (RC/GS Only)
The RC/GS can be configured so that the RV Series Inverter/ Charger stops the generator automatically when the charger initiates the Absorption or the Float mode of charging. Refer to the RV Series Inverter/Charger Owner’s Manual for a detailed description of charging modes. The default is Manual (Push Off).
Generator Stop: | Generator Stop: | Generator Stop: |
Manual (Push OFF) | Auto at Absorb | Auto at Float |
Figure 3-14 Generator Stop menu items