Configuration
Select Genset: | Select Genset: | Select Genset: |
Onan QuietDiesel | PowerTech Diesel | Generac Diesel |
Figure 3-11 Select Genset menu items
Generator Start (RC/GS Only)
After setting the clock and selecting a generator, set the parameters for automatically starting the generator based upon a battery voltage. Press the up arrow and scroll through the menus to view the Generator Start menu. Press the Settings button to select the required setting.
Note: You cannot set the Auto Gen parameters until you set the clock.
Note: When the battery voltage drops to the selected generator start setting, there is a
The default Generator Start selection is Manual (Push ON). This setting disables all automatic start functions. Any other selection from the Generator Start menu enables the RV Series Inverter/Charger to automatically start the generator based upon the battery’s voltage.
The available auto start voltage settings are 11.0, 11.5, 11.8, 12.0, and 12.2 VDC.
Generator Start: | Generator Start: | Generator Start: | Generator Start: |
Manual (Push ON) | Auto at 11.0 VDC | Auto at 11.5 VDC | Auto at 12.2 VDC |
Figure 3-12 Generator Start menu items