Operation
Genset Error Messages (RC/GS Only)
Gen Won’t Start
If the generator does not start after the three attempts, the RC/ GS displays the message “Gen won’t Start” and the red Error LED on the front panel lights. After displaying this message, the RC/GS automatically sets the Generator Start menu to “Manual (Push ON)” and no further attempts to start the generator will occur. Correct the starting problem and set the RC/GS back to the previous
Inverter
Charge
Batt. Full
Error
Genset Status: !
Gen wont Start
Buzzer sounds
Red Error LED lights and error message appears in the screen
Figure 4-4 Gen Won’t Start Error Message
Note: Press any arrow button to cancel the buzzer.
Gen Quiet Fault
If the generator has started in response to an auto start setting and is running when quiet time begins, it shuts down automatically. The buzzer also sounds and the screen shows the message “Gen Quiet Fault” and the red Error LED comes on. The remote control also emits a series of beeping sounds for up to five minutes (press any arrow button on the RC/GS to stop the alarm). If the