Operation
Batt. Full LED
The yellow Batt. Full LED indicates the state of charge on the batteries. This LED will not illuminate until the batteries have charged up to at least 90% (according to the inverter/charger’s estimate). The duration of the LED’s on time will increase until the batteries reach 100%, at which time the LED will be on solid. In the inverter mode, the off time duration of the LED will increase until the batteries discharge to below 90%, at which time the LED will turn off.
| Other LEDs or |
|
Batt. Full LED | Devices | Meaning |
|
|
|
Solid |
| Battery fully charged (100%) |
|
|
|
Flashing | Yellow charge | Battery charged 90% or higher |
| LED (flashing) |
|
|
|
|
OFF |
| Battery below 90% charge |
|
|
|
Error LED
The Error LED indicates that there is a problem with the inverter/charger, batteries or generator. Check the LCD screen to find and correct the nature of the problem. For more information, see “Genset Error Messages (RC/GS Only)” on page 32 and “Inverter/Charger Error Messages” on page 37.
Error | Other LEDs or Devices | Meaning |
|
|
|
ON (Solid) |
| Check system |
|
|
|
LCD Screen
The screen is used for setting up the system operation as well as viewing current status or error messages. It has two 16- character lines and a backlight. You can scroll through the screen items by using the buttons below the screen.
System Status:
Equalizing
Figure 4-2 LCD screen
28 |