AMX AXB-TC manual Wiring guidelines, Preparing/connecting captive wires, TV Sensor connections

Page 11

Installation and Wiring

Wiring

The TV sensor, IR emitter, AXlink, and 12 VDC power supply connectors are located on the rear panel of the television controller as shown in FIG. 1 on page 1.

Do not connect power directly to the television controller. If you are using power from AXlink, disconnect the wiring from the Central Controller before connecting the wiring to the television controller. If you are using an optional 12 VDC power supply, apply power to the television controller only when installation is complete.

Wiring guidelines

The television controller requires 12 VDC power to operate properly. The power can be supplied via AXlink cable, or with an optional 12 VDC power supply. The maximum wiring distance between the Central Controller and television controller is determined by power consumption, supplied voltage, and the wire gauge used for the cable.

The following table lists wire sizes and the maximum lengths allowable between the television controller and Central Controller. The maximum wiring lengths are based on a minimum of

13.5volts available at the Central Controller's power supply. If a television controller is installed farther away from the Central Controller than recommended in the table, connect a 12 VDC power supply to the 2-pin 12 VDC PWR connector on the rear panel.

Wiring Guidelines - TC - 175 mA

Wire size

Maximum wiring

 

length

 

 

18 AWG

670.69 feet (204.43 meters)

 

 

20 AWG

424.33 feet (129.34 meters)

 

 

22 AWG

264.55 feet (80.63 meters)

 

 

24 AWG

166.76 feet (50.83 meters)

 

 

Wiring Guidelines - TCR - 200 mA

Wire size

Maximum wiring

 

length

 

 

18 AWG

586.55 feet (178.78 meters)

 

 

20 AWG

371.29 feet (113.17 meters)

 

 

22 AWG

231.48 feet (70.56 meters)

 

 

24 AWG

145.91 feet (44.47 meters)

 

 

Preparing/connecting captive wires

1.Strip 0.25 inch of wire insulation off all wires.

2.Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section.

Do not tighten the screws excessively; doing so may strip the threads and damage the connector.

TV Sensor connections

Connect the CC-IR to the TV Sensor connector, on the rear panel of the television controller, as shown in FIG. 2 to detect horizontal scan frequencies up to 65 kHz.

TV SENSOR

GND

 

 

Television

 

 

 

 

 

connector

SEN

 

 

 

 

 

 

CC-IR

 

 

FIG. 2 CC-IR TV Sensor connector wiring diagram

 

 

 

AXB-TC and AXB-TCR Television Controllers (& Receivers)

7

 

 

Image 11
Contents AXB-TC and AXB-TCR AMX Limited Warranty and Disclaimer Table of Contents AXB-TC and AXB-TCR Television Controllers & Receivers Overview AXB-TC and AXB-TCR Television ControllersAXB-TC/TCR Specifications SpecificationsAXB-TC AXB-TCR ApplicationsAXB-TC and AXB-TCR Television Controllers DIP Switch Settings Setting the Device DIP SwitchInternal Jumper Settings J3 Jumper Settings IR Attenuation Mode Bypass or Adjustment J3 jumper settings IR attenuation mode bypass or adjustmentTV Sensor connections WiringWiring guidelines Preparing/connecting captive wiresIR Emitter connections Axlink data and power connectionsAxlink data and 12 VDC power supply connections PCS and 12 VDC power supply connections PCS and Axlink data and power connectionsSE-TC mounting dimensions InstallationIR Signal Attenuation Adjustment Television Power Sensor AdjustmentLithium battery and socket Replacing the Lithium BatteryInstallation and Wiring Installation and Wiring Channel Setting Commands Channel Setting CommandsIR Functions Standard Order IR Functions Standard OrderSendCommands SendCommands?CTON ?PTOF XCH Channel Using Softrom Firmware UpgradesUsing NetLinx Studio Upon completion of the upgrade, press F10 to exit SoftromProgramming Information It’s Your World Take Control