AMX AXB-TCR manual Setting the Device DIP Switch, Internal Jumper Settings, DIP Switch Settings

Page 9

Installation and Wiring

Installation and Wiring

Setting the Device DIP Switch

The eight-position Device DIP switch sets the identification number for the television controller. Make sure the device number matches the number assigned in the AXCESS software program. The quick reference table below shows the switch positions and their numeric value. In the example below, the numeric value of the Device DIP switch is 97 (1+32+64=97).

DIP Switch Settings

Switch

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

Value

1

2

4

8

16

32

64

128

 

 

 

 

 

 

 

 

 

DEVICE

1 2 3 4 5 6 7 8 ON

Internal Jumper Settings

The internal jumpers, located on the circuit card inside the television controller enclosure, set the input, output, and IR attenuation modes. Internal jumper modes include:

Jumper JP1 sets the input mode for power sensing or power current sensing.

Jumper JP2 sets the IR output mode for IR or serial communication.

Jumper JP3 sets the IR attenuation mode for bypass or adjustment.

Use a Phillips-head screwdriver to open the enclosure and non-conducting pliers to set the jumpers.

Static electricity can damage electronic circuitry. Before removing the enclosure, discharge any accumulated static electricity from your body by touching a grounded metal object.

1.Unplug all connectors from the rear panel of the television controller.

2.Remove the two Phillips-head screws on the bottom of the enclosure.

3.Pull the two enclosure halves apart and set the bottom portion of the enclosure on a flat surface. FIG. 1 shows the location of the internal jumpers.

JP1 jumper

JP3 jumper

JP2 jumper

front

FIG. 1 Internal jumper locations

4.Replace the top portion of the enclosure on the bottom portion. Then, refasten the two Phillips-head screws.

AXB-TC and AXB-TCR Television Controllers (& Receivers)

5

 

 

Image 9
Contents AXB-TC and AXB-TCR AMX Limited Warranty and Disclaimer Table of Contents AXB-TC and AXB-TCR Television Controllers & Receivers Overview AXB-TC and AXB-TCR Television ControllersAXB-TC/TCR Specifications SpecificationsAXB-TC AXB-TCR ApplicationsAXB-TC and AXB-TCR Television Controllers Setting the Device DIP Switch Internal Jumper SettingsDIP Switch Settings J3 Jumper Settings IR Attenuation Mode Bypass or Adjustment J3 jumper settings IR attenuation mode bypass or adjustmentWiring guidelines WiringPreparing/connecting captive wires TV Sensor connectionsAxlink data and power connections Axlink data and 12 VDC power supply connectionsIR Emitter connections PCS and 12 VDC power supply connections PCS and Axlink data and power connectionsSE-TC mounting dimensions InstallationIR Signal Attenuation Adjustment Television Power Sensor AdjustmentLithium battery and socket Replacing the Lithium BatteryInstallation and Wiring Installation and Wiring Channel Setting Commands Channel Setting CommandsIR Functions Standard Order IR Functions Standard OrderSendCommands SendCommands?CTON ?PTOF XCH Channel Using Softrom Firmware UpgradesUsing NetLinx Studio Upon completion of the upgrade, press F10 to exit SoftromProgramming Information It’s Your World Take Control