5-7. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag | 01H |
DATA01: CONTRAST Gain Flag | 07H |
DATA02: CONTRAST Gain | CCH: |
| : |
| FFH: |
| 00H: 0 |
| 01H: +01 |
| : |
| 14H: +20 |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 01H |
DATA01: CONTRAST Gain Flag | 07H |
5-8. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag | 01H |
DATA01: BRIGHT Gain Flag | 08H |
DATA02: BRIGHT Gain | E0H: |
| : |
| FFH: |
| 00H: 0 |
| 01H: +01 |
| : |
| 20H: +32 |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 01H |
DATA01: BRIGHT Gain Flag | 08H |