PDxx01 | Page: 16 / 49 |
Document Version [1.0]
5-19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA0 CKS
DATA00: USER PICTURE Gain Flag | 05H |
DATA01: TREBLE Gain Flag | 04H |
DATA02: TREBLE Gain | F3H: |
| : |
| FFH: |
| 00H: 0 |
| 01H: +01 |
| : |
| 0DH: +13 |
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag | 05H |
DATA01: TREBLE Gain Flag | 04H |
5-20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
| DATA00: USER PICTURE Gain Flag | 05H |
| DATA01: BALANCE Gain Flag | 02H |
| DATA02: BALANCE Gain | EAH: |
|
| : |
|
| FFH: |
|
| 00H: 0 |
|
| 01H: +01 |
|
| : |
|
| 16H: +22 |
ACK |
| |
|
| |
| 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS | |
| DATA00: USER PICTURE Gain Flag | 05H |
| DATA01: BALANCE Gain Flag | 02H |
Company Restricted