PDxx01 | Page: 41 / 49 |
Document Version [1.0]
5-61. PICTURE FREEZE (Pause) Command
Function
External control apparatus sets picture freeze or remove picture freeze of a plasma monitor.
Transmission Data
DFH 80H 60H 7DH 01H DATA00 CKS
DATA00 01H: FREEZE 02H: FREEZE OFF
ACK
7FH 60H 80H 7DH 01H DATA00 CKS
DATA00 01H: FREEZE 02H: FREEZE OFF
5-62. OSM CONTRAST SELECT
Function
External control apparatus selects the OSM contrast function of a plasma monitor.
Transmission Data
DFH 80H 60H 37H 01H DATA00 CKS
DATA00 01H: NORMAL 02H: LOW
ACK
7FH 60H 80H 37H 01H DATA00 CKS
DATA00 01H: NORMAL 02H: LOW
5-63. CC (Closed caption) SELECT
Function
External control apparatus selects the Closed Caption function of a plasma monitor.
Transmission Data
DFH 80H 60H 3CH 01H DATA00 CKS
DATA00 00H: OFF
01H: CC1 (closed caption1)
02H: CC2 (closed caption2)
03H: CC3 (closed caption3)
04H: CC4 (closed caption4)
05H: TEXT1
06H: TEXT2
07H: TEXT3
08H: TEXT4