Marantz PDxx01 specifications CC Closed caption Contrast Select, Picture Memory Select

Page 42

PDxx01

RS-232C Control Specification

Page: 42 / 49

Document Version [1.0]

ACK

7FH 60H 80H 3CH 01H DATA00 CKS

DATA00 00H: OFF

01H: CC1 (closed caption1)

02H: CC2 (closed caption2)

03H: CC3 (closed caption3)

04H: CC4 (closed caption4)

05H: TEXT1

06H: TEXT2

07H: TEXT3

08H: TEXT4

5-64.CC (Closed caption) CONTRAST SELECT

Function

External control apparatus selects the Closed Caption Contrast function of a plasma monitor.

Transmission Data

DFH 80H 60H 3DH 01H DATA00 CKS

DATA00 01H: NORMAL 02H: LOW

ACK

7FH 60H 80H 3DH 01H DATA00 CKS

DATA00 01H: NORMAL 02H: LOW

5-65.PICTURE MEMORY Select

Function

The external control equipment selects the Picture Memory function of a plasma monitor.

Transmission Data

DFH 80H 60H 38H 01H DATA00 CKS

DATA00: MEMORY select 00H: OFF 01H: MEMORY1

02H: MEMORY2

03H: MEMORY3

04H: MEMORY4

05H: MEMORY5

06H: MEMORY6

ACK

The plasma monitor returns the following ACK when the input is switched. 7FH 60H 80H 38H 01H CKS

DATA00:

00H: OFF

 

01H: MEMORY1

 

02H: MEMORY2

 

03H: MEMORY3

 

04H: MEMORY4

 

05H: MEMORY5

 

06H: MEMORY6

Company Restricted

Image 42
Contents PDxx01 RS-232C Control Specification Table of Contents Revision history Wiring Communication ParametersConnections should be made as described below Check Sum CKS, Error Processing, and ACK Command1Command Unit ID1,2 UA1,UA2Command Reference List Picture Freeze DFH 7CH Power on Power OFFInput Switch Change Volume Gain Data Audio Mute onAudio Mute OFF Contrast Gain Data Bright Gain DataSharpness Gain Data Color Gain DataDFH 80H 60H 0AH 01H DATA00 CKS Picture Mode SelectTint Gain Data 7FH 60H 80H 0AH 01H DATA00 CKSDFH 80H 60H 00H 01H DATA00 CKS Color Temp SelectRED Gain Data 7FH 60H 80H 00H 01H DATA00 CKSGreen Gain Data Blue Gain DataDFH 80H 60H C0H 01H DATA00 CKS NR Mode SetBass Gain Data 7FH 60H 80H C0H 01H DATA00 CKSTreble Gain Data Balance Gain DataDFH 80H 60H 51H 01H DATA00 CKS Screen Mode Select22.V. Position Gain Data 7FH 60H 80H 51H 01H DATA00 CKS23.H. Position Gain Data 24.V. Height Gain Data25.H. Width Gain Data Phase Fine Picture Gain Data Auto Picture Select7FH 60H 80H 7FH 03H DATA00 DATA01 DATA02 CKS OSM ADJ. Position Data Clock Picture Adjust Gain DataPower MGT Select 7FH 60H 80H 1AH 01H DATA00 CKSCinema Mode Set Gray Level SetLong Life Set PDP Saver Set ALL Reset Screen Wiper SetAudio Select Set DFH 80H 60H 70H 02H DATA00 DATA01 CKSRGB Select DFH 80H 60H 8BH 01H DATA00 CKS7FH 60H 80H 8BH 01H DATA00 CKS Vmode:7 @70 @72 Mode:10 1024×768 1152×864 Mode:8 @75 HD Select Language SelectFrequency Request Signal Information Color System Select58NTSC 82H 43NTSC 83H 01H to 80H RGB signal81H 84HInput Mode Request Video ADJ. RequestPDxx01 RS-232C Control Specification Document Version Audio Select Request 1FH 80H 60H 6FH 00H CKS7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS Failure Mode Request 1FH 80H 60H 3FH 00H CKS7FH 60H 80H 3FH 02H DATA00 DATA01 CKS Model Name Request 1FH 80H 60H 17H 00H CKS7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS DFH 80H 60H 0CH 01H DATA00 CKS LOW Tone 50inch onlyColor Tune 7FH 60H 80H 0CH 01H DATA00 CKSGamma Gain Data Running SenseOSM Orbiter Input SkipSerial No. Request 54.S1/S2 Select Soft FocusBlack Level Select Multi Sprit Screen Select DFH 80H 60H 07H 01H DATA00 CKS DFH 80H 60H 7AH 01H DATA00 CKS SUB Picture Detect Select 7FH 60H 80H 07H 01H DATA00 CKS 7FH 60H 80H 7AH 01H DATA00 CKSDFH 80H 60H 7BH 01H DATA00 CKS Zoom Navigation SelectPicture Freeze Select DFH 80H 60H 7CH 01H DATA00 CKSPicture Freeze Pause Command OSM Contrast SelectCC Closed caption Select CC Closed caption Contrast Select Picture Memory SelectPicture Memory Set Picture Memory Note Write SetDFH 80H 60H 25H 02H DATA00 DATA01 CKS SET UP Level Select Back Ground SelectPower on Mode Input PDP Saver Auto SelectAudio Hdmi Request DFH 80H 60H 0FH 01H DATA00 CKS Power on Mode VolumeSUB Picture Rate set 7FH 60H 80H 0FH 00H CKSMulti Sprit Screen Power on Mode SET DFH 80H 60H 33H 04H DATA00 to DATA03 CKS7FH 0H 80H 33H 00H CKS Remote Code Setting Volume Gain Data RequestUnder Scan Setting Revision history