PDxx01 | Page: 27 / 49 |
Document Version [1.0]
5-40. COLOR SYSTEM Select
Function
The external control equipment sets the COLOR SYSTEM of the plasma monitor.
Transmission Data
DFH 80H 60H 5CH 01H DATA00 CKS
DATA00: 01H: 3.58NTSC 02H: 4.43NTSC
03H: PAL
04H: SECAM
0AH: AUTO
0BH: PAL60
0DH:
0EH:
ACK
7FH 60H 80H 5CH 01H DATA00 CKS
DATA00: 01H: 3.58NTSC 02H: 4.43NTSC
03H: PAL
04H: SECAM
0AH: AUTO
0BH: PAL60
0DH:
0EH:
5-41. FREQUENCY Request (SIGNAL INFORMATION)
Function
The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma monitor.
Transmission Data
1FH 80H 60H 26H 00H CKS
ACK |
| |
| 7FH 60H 80H 26H 0BH | DATA00 to DATA0A CKS |
Horizontal frequency |
| |
| DATA00: Integer part | 00H: 0 (No signal: 00H) |
|
| : |
|
| FFH: 255 |
| DATA01: One decimal place | 00H: 0 (No signal: 00H) |
|
| : |
|
| 09H: 9 |
Vertical frequency |
| |
| DATA02: Integer part | 00H: 0 (No signal: 00H) |
|
| : |
|
| FFH: 255 |
| DATA03: One decimal place | 00H: 0 (No signal: 00H) |
|
| : |
|
| 09H: 9 |
Company Restricted